Sample Record

Owner Lab

  • CT D08 - Fontana Southern Regional Laboratory

DIME Sample ID 2021-04-28-2

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214921
DEA: 09367404
EFIS: 0916000025
DIST-CO-RTE-PM09-KER-14-R4.7/R12.6
Award DateNot set
Closeout Date01/23/2023
Work DescriptionCONSTRUCT CRCP OVER EXISTING PAVEMENT AND PLACE HMA.
Location DescriptionKERN COUNTY AT AND NEAR ROSAMOND AND MOJAVE FROM 1.4 MILES SOUTH OF DAWN ROAD OVERCROSSING TO 0.5 MILE NORTH OF SILVER QUEEN ROAD OVERCROSSING
QA Service Level1 (Verified on 11/06/2020)

Sample Information

Sample Taken Date04/28/2021 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/29/2021
Sample typeVerification A brief description of the samplePSUE 3/4" HMA-A-SP R25 0.8% Lime
The quantity of what the sample constitutes2 Bags Virgin Agg., 1 Bag Coldfeed Agg., 1 Bag Rap From where was the sample collectedManufacturer
First name of sampler or witnessed byWillam Last name of sampler or witnessed byLucas
Title of sampler Telephone number of sampler
Laboratory sample identification0245A-21 Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite Construction Co Bigrock Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0008, 91-19-0046
The fabricator's/manufacturer's product name for the sample3/4 HMA-A-SP R25 The fabricator/manufacturer designation for the sample
The plant number13554 A detailed description of where the material sample was collectedBelt Cut at Granite-Bigrock
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2021-04-28-2-11AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)Satish Jain, CT D08 - Fontana Southern Regional Laboratory05/02/2021Michael Magana
Yes
05/04/2021

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2021-04-28-2-1 AASHTO T27-14 (Verified)
DIME Test ID: 2021-04-28-2-2 AASHTO T335-09r13 (Verified)
DIME Test ID: 2021-04-28-2-3 AASHTO T85-13 (Verified)
DIME Test ID: 2021-04-28-2-4 AASHTO T84-14 (Verified)
DIME Test ID: 2021-04-28-2-5 AASHTO T96-02r10 (Verified)
DIME Test ID: 2021-04-28-2-6 AASHTO T176-08 (Verified)
DIME Test ID: 2021-04-28-2-7 ASTM D4791-10 (Verified)
DIME Test ID: 2021-04-28-2-8 AASHTO T304-11 (Verified)
DIME Test ID: 2021-04-28-2-9 CTM 202-November 2011 (Verified)
DIME Test ID: 2021-04-28-2-10 CTM 202-November 2011 (Verified)
DIME Test ID: 2021-04-28-2-11 AASHTO T335-09r13 (Verified)