Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2021-01-06-4

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214937
DEA: 11288834
EFIS: 1117000088
DIST-CO-RTE-PM11-SD-11,125,905-various
Award Date07/28/2020
Closeout Date03/05/2024
Work DescriptionCONSTRUCT CONCRETE BRIDGE, PAVEMENT, BARRIER, AND INSTALL LIGHTING. HPLUL-6211(133) SR-125 SB to WB SR-905
Location DescriptionSAN DIEGO COUNTY IN AND NEAR SAN DIEGO AT ROUTE 11/125/905 SEPARATION
QA Service Level1 (Verified on 09/04/2020)

Sample Information

Sample Taken Date01/06/2021 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/07/2021
Sample typeQuality Assurance A brief description of the sampleErico End Anchor Heads
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byNikku Last name of sampler or witnessed byTiongco
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCMC Rebar Erico Transportation Laboratory (TL) NumberC
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)1066926 Head Manufacturer Lot Number(s)A1220
Rebar Size#14 Headed Bar Model NameLenton EL 43TD14 T2
Size of HeadFull Size - 9x Head Connection TypeThreaded
Head ShapeCircular Rebar ManufacturerCMC Rebar
Head ManufacturerErico Head FabricatorErico
Material Standard CodeASTM A706 Headed Bar Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2021-01-06-4-1ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory01/08/2021fsaylor
Yes
01/11/2021Head Pull Off
2021-01-06-4-2ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory01/08/2021fsaylor
Yes
01/11/2021Head Pull Off
2021-01-06-4-3ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory01/08/2021fsaylor
Yes
01/11/2021Head Pull Off
2021-01-06-4-4ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory01/08/2021fsaylor
Yes
01/11/2021Head Pull Off

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2021-01-06-4-1 ASTM A970-15e1 (Verified)
DIME Test ID: 2021-01-06-4-2 ASTM A970-15e1 (Verified)
DIME Test ID: 2021-01-06-4-3 ASTM A970-15e1 (Verified)
DIME Test ID: 2021-01-06-4-4 ASTM A970-15e1 (Verified)