Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2020-12-30-1

Project Information

Project IdentifiersProject ID: 211848
DEA: 112T2174
EFIS: 1116000131
DIST-CO-RTE-PM11-SD-5-R37.4 - R46.5
Award DateNot set
Closeout DateNot set
Work Description(Alternative Delivery) CMGC, San Elijo Highway Bridge Replacement. Replace the San Elijo lagoon highway bridge, construct HOV lanes, construct bike and pedestrian trails and bridge, build multi-use facility at Manchester Ave.
Location DescriptionIN SAN DIEGO COUNTY IN SOLANA BEACH AND ENCINITAS FROM 0.1 MILE NORTH OF LOMAS SANTA FE DRIVE OVERCROSSING TO 0.2 MILE SOUTH OF BIRMINGHAM DRIVE OVERCROSSING
QA Service Level1 (Verified on 01/31/2017)

Sample Information

Sample Taken Date12/30/2020 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing01/04/2021
Sample typeQuality Assurance A brief description of the sample#11 HRC 500/510 Coupler
The quantity of what the sample constitutes54 Couplers From where was the sample collectedSource
First name of sampler or witnessed byMichael Last name of sampler or witnessed byCattabiani
Title of sampler Telephone number of sampler2016746612
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCMC San Bernardino Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC Steel California
Coupler ManufacturerHRC Intermediate Assembler or Fabricator
Rebar Size#11 Coupler ModelHRC 500/510
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)500-73116792, A196205, 510-73117653, 73115502 Rebar Heat Number(s)3100296
Rebar Size 2 11

Submitted Tests

DIME Test IDTest MethodTester NameTesting LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2020-12-30-1-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)fsaylorCT HQ - Sacramento Structural Materials Testing Laboratory01/05/2021fsaylor
Yes
01/06/2021OK Necking
2020-12-30-1-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)fsaylorCT HQ - Sacramento Structural Materials Testing Laboratory01/05/2021fsaylor
Yes
01/06/2021OK Necking
2020-12-30-1-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)fsaylorCT HQ - Sacramento Structural Materials Testing Laboratory01/05/2021fsaylor
Yes
01/06/2021OK Necking