Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2020-11-02-19

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214465
DEA: 081E5704
EFIS: 0814000051
DIST-CO-RTE-PM08-RIV-10-27.7
Award Date12/26/2019
Closeout Date09/15/2021
Work DescriptionPLACE CIDH PILING AND ROCK SLOPE PROTECTION
Location DescriptionRIVERSIDE COUNTY NEAR PALM SPRINGS AT WHITEWATER RIVER BRIDGE
QA Service Level1 (Verified on 02/28/2020)

Sample Information

Sample Taken Date11/02/2020 Sample Unique Key19
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/18/2020
Sample typeQuality Assurance A brief description of the sampleHRC 500/510
The quantity of what the sample constitutes150 Couplers From where was the sample collectedJob Site
First name of sampler or witnessed byShukri Last name of sampler or witnessed byAboyazra
Title of samplerSR Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameHRC Transportation Laboratory (TL) NumberC411164
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCascade Steel
Coupler ManufacturerHRC Intermediate Assembler or Fabricator
Rebar Size#9 Coupler ModelHRC 500/510
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)A193741, 73116792 Rebar Heat Number(s)373119
Rebar Size 2 Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2020-11-02-19-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory11/18/2020fsaylor
Yes
11/18/2020OK Necking
2020-11-02-19-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory11/18/2020fsaylor
Yes
11/18/2020OK Necking
2020-11-02-19-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory11/18/2020fsaylor
Yes
11/18/2020OK Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2020-11-02-19-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2020-11-02-19-2 CTM 670-December 2013 (Verified)