Sample Record
Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
DIME Sample ID 2020-09-28-17
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 214176 DEA: 033F0904 EFIS: 0312000056 |
---|---|
DIST-CO-RTE-PM | 03-SAC,SJ-5,160-Var |
Award Date | 10/10/2019 |
Closeout Date | 10/27/2022 |
Work Description | REPLACE STRUCTURAL CONCRETE BRIDGES, PLACE CIDH & CISS CONCRETE PILES. |
Location Description | SACRAMENTO COUNTY AT NORTH SACRAMENTO UNDERCROSSING AND SACRAMENTO RIVER BRIDGE AND IN SAN JOAQUIN COUNTY AT MOKELUMNE RIVER BRIDGE |
QA Service Level | 1 (Verified on 05/29/2019) |
Sample Information
Sample Taken Date | 09/28/2020 | Sample Unique Key | 17 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/28/2020 |
Sample type | Quality Assurance | A brief description of the sample | Dextra T-Head |
The quantity of what the sample constitutes | 16 splices | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Chuck | Last name of sampler or witnessed by | Pazzi |
Title of sampler | Structures Rep | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Myers and Sons Construction | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Production Testing |
---|---|---|---|
Rebar Heat Number(s) | 3096949 | Head Manufacturer Lot Number(s) | 5076 |
Rebar Size | #8 | Headed Bar Model Name | Large End Anchor |
Size of Head | Full Size - 9x | Head Connection Type | Threaded |
Head Shape | Circular | Rebar Manufacturer | CMC Rebar |
Head Manufacturer | Dextra America | Head Fabricator | Dextra America |
Material Standard Code | ASTM A706 | Headed Bar Unique ID | Not set |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2020-09-28-17-1 ASTM A970-15e1 (Verified)
DIME Test ID: 2020-09-28-17-2 ASTM A970-15e1 (Verified)