Sample Record

Owner Labs

  • Kwik Bond Polymers
  • CT HQ - Sacramento Concrete Testing Laboratory

DIME Sample ID 2020-08-04-26

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214352
DEA: 07332704
EFIS: 0716000290
DIST-CO-RTE-PM07-LA-5-18.3
Award Date11/27/2019
Closeout Date11/21/2022
Work DescriptionAPPLY HIGH FRICTION SURFACE TREATMENT, LANDSCAPE, & IRRIGATION WORK.
Location DescriptionLOS ANGELES COUNTY IN LOS ANGELES ON ROUTE 5
QA Service Level1 (Verified on 06/15/2020)

Sample Information

Sample Taken Date08/04/2020 Sample Unique Key26
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/04/2020
Sample typeQuality Control A brief description of the sample1 gallon can
The quantity of what the sample constitutes34 Totes From where was the sample collectedSource
First name of sampler or witnessed byDaniel Last name of sampler or witnessed byTikusis
Title of samplerTechnical Director Telephone number of sampler7073309227
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameKwik Bond Polymers and Reichhold Transportation Laboratory (TL) NumberSacramento Caltrans lab
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypePolyester Mfg. Lot Number(s)1269608
Batch number1269608 Mix number1269608

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2020-08-04-26-1ASTM D2196-Feb15: Standard Test Methods for Rheological Properties of Non-Newtonian Materials by Rotational ViscometerRachael Chavez, CT HQ - Sacramento Concrete Testing Laboratory10/30/2020Spencer Adams
Yes
12/04/2020
2020-08-04-26-2ASTM D638-Dec14: Standard Test Method for Tensile Properties of PlasticsPhil Montes, CT HQ - Sacramento Concrete Testing Laboratory10/30/2020Spencer Adams
Yes
12/04/2020Specimens 2, 3 & 5 not used due to flaws. Averages below based on Specimens 1 & 4. Average Strength: 3500.5 psi / Average Elongation: 41.5%

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2020-08-04-26-1 ASTM D2196-Feb15 (Verified)
DIME Test ID: 2020-08-04-26-2 ASTM D638-Dec14 (Verified)