Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2020-08-14-5

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 213702
DEA: 041G4304
EFIS: 0412000126
DIST-CO-RTE-PM04-NAP-128-R7.4
Award Date03/29/2019
Closeout Date12/08/2022
Work DescriptionREPLACE BRIDGE, HMA PAVING, DRAINAGE AND RSP
Location DescriptionNAPA COUNTY NEAR SAINT HELENA AT CONN CREEK
QA Service Level1 (Verified on 07/29/2019)

Sample Information

Sample Taken Date08/14/2020 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/17/2020
Sample typeQuality Assurance A brief description of the sample Dayton Superior Zap Screw Lock Couplers
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byNana Last name of sampler or witnessed byBudu
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameDayton Superior CMC Rebar Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC Rebar
Coupler ManufacturerDayton Superior Intermediate Assembler or Fabricator
Rebar Size#10 Coupler ModelZap Screwlok
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)181728-1 Rebar Heat Number(s)3096266
Rebar Size 2 Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2020-08-14-5-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory08/17/2020fsaylor
Yes
08/17/2020Service Splice
2020-08-14-5-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory08/17/2020fsaylor
Yes
08/17/2020Service Splice
2020-08-14-5-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory08/17/2020fsaylor
Yes
08/17/2020Service Splice

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2020-08-14-5-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2020-08-14-5-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2020-08-14-5-3 CTM 670-December 2013 (Verified)