Sample Record
Owner Lab
- Sequoia Consultants
DIME Sample ID 2020-06-12-22
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 214756 DEA: 050N7AU4 EFIS: 0520000030 |
---|---|
DIST-CO-RTE-PM | 05-SB-101-1.4/4.8 |
Award Date | Not set |
Closeout Date | 09/27/2022 |
Work Description | Segment 4A - Carpinteria: Construct HOV lanes and rehabilitation. Source inspection of sign structure trusses, lighting structures, epoxy coated rebar, precast box culverts, precast RCP. |
Location Description | CARPINTERIA FROM 0.2 MILE SOUTH OF BAILARD AVENUE OVERCROSSING TO 0.7 MILE SOUTH OF SOUTH PADARO LANE |
QA Service Level | 1 (Verified on 03/09/2020) |
Sample Information
Sample Taken Date | 06/12/2020 | Sample Unique Key | 22 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/13/2020 |
Sample type | Quality Control | A brief description of the sample | 6x12 concrete cylinders |
The quantity of what the sample constitutes | 92 cy | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Zac | Last name of sampler or witnessed by | Flores |
Title of sampler | QC Technician | Telephone number of sampler | |
Laboratory sample identification | C061220-404, 405, 406 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Hanson - Goleta | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name | Franklin and Santa Monica |
Material Information
Material Type | Concrete | The concrete mix design number | 725A1MOP |
---|---|---|---|
The truck number from where the sample was collected | 514D | The batch plant ticket number from where the sample was collected | 35252 |
Concrete batch plant | Hanson Aggregates | The fabricator/manufacturer designation for the sample | |
A detailed description of where the material sample was collected | Point of Placement | Where the material sample would have been placed if not sampled | Abutment 1 and 2 |
From Lot No. | Bag Lot No. |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2020-06-12-22-1 CTM 521-June 2012 (Verified)
DIME Test ID: 2020-06-12-22-2 CTM 521-June 2012 (Verified)
DIME Test ID: 2020-06-12-22-3 CTM 521-June 2012 (Verified)