Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
DIME Sample ID 2020-06-24-6
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 214841 DEA: 034H1004 EFIS: 0318000176 |
DIST-CO-RTE-PM | 03-SIE-49-9.2/24.7 |
Award Date | 05/29/2020 |
Closeout Date | 07/29/2022 |
Work Description | INSTALL RETAINING STRUCTURE AND RSP CONCRETE EMBANKMENT. |
Location Description | SIERRA COUNTY ON ROUTE 49 AT VARIOUS LOCATIONS |
QA Service Level | 1 (Verified on 03/24/2020) |
Sample Information
Sample Taken Date | 06/24/2020 |
Sample Unique Key | 6 |
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes |
Date that the sample was received by the laboratory/organization performing the testing | 06/24/2020 |
Sample type | Quality Assurance |
A brief description of the sample | Double headed rebar |
The quantity of what the sample constitutes | 320 |
From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Paul |
Last name of sampler or witnessed by | Farinha |
Title of sampler | Asi |
Telephone number of sampler | |
Laboratory sample identification | |
Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Pacific Steel Group |
Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | S51-37-20 |
Structure unique identifier | |
Structure name | |
---|
Material Information
Material Type | SMTL TM5 - Headed Bars |
Production or Authorization Testing | Production Testing |
Rebar Heat Number(s) | 35000084422 |
Head Manufacturer Lot Number(s) | 1,2 and 3 |
Rebar Size | #8 |
Headed Bar Model Name | HRC 555 |
Size of Head | Reduced Size - 4x |
Head Connection Type | Forged |
Head Shape | Circular |
Rebar Manufacturer | Nucor |
Head Manufacturer | Pacific Steel Group |
Head Fabricator | Pacific Steel Group |
Material Standard Code | ASTM A706 |
---|
Submitted Tests
DIME Test ID | Test Method | Tester Name | Testing Lab | Date Tested | Submitted By | Verified? | Release Date | Test Comments | Actions |
2020-06-24-6-1 | ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile) | bewing | CT HQ - Sacramento Structural Materials Testing Laboratory | 06/29/2020 | bewing | Yes | 07/01/2020 | Ok | |
2020-06-24-6-2 | ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile) | bewing | CT HQ - Sacramento Structural Materials Testing Laboratory | 06/29/2020 | bewing | Yes | 07/01/2020 | Ok Necking | |
2020-06-24-6-3 | ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile) | bewing | CT HQ - Sacramento Structural Materials Testing Laboratory | 06/29/2020 | bewing | Yes | 07/01/2020 | Ok Necking | |
2020-06-24-6-4 | ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile) | bewing | CT HQ - Sacramento Structural Materials Testing Laboratory | 06/29/2020 | bewing | Yes | 07/01/2020 | Ok Necking | |
2020-06-24-6-5 | ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile) | bewing | CT HQ - Sacramento Structural Materials Testing Laboratory | 06/29/2020 | bewing | Yes | 07/01/2020 | Ok Necking | |
2020-06-24-6-6 | ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile) | bewing | CT HQ - Sacramento Structural Materials Testing Laboratory | 06/29/2020 | bewing | Yes | 07/01/2020 | Ok Necking | |
2020-06-24-6-7 | ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile) | bewing | CT HQ - Sacramento Structural Materials Testing Laboratory | 06/29/2020 | bewing | Yes | 07/01/2020 | Ok Necking | |
2020-06-24-6-8 | ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile) | bewing | CT HQ - Sacramento Structural Materials Testing Laboratory | 06/29/2020 | bewing | Yes | 07/01/2020 | Ok Necking | |
2020-06-24-6-10 | ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile) | bewing | CT HQ - Sacramento Structural Materials Testing Laboratory | 06/29/2020 | bewing | Yes | 07/01/2020 | Ok Necking | |
852278523185235852378523985240852418524285244