Sample Record

Owner Lab

  • CT HQ - QASI Los Angeles Field Office

DIME Sample ID 2020-06-16-8

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214543
DEA: 080K8404
EFIS: 0800020563
DIST-CO-RTE-PM08-SBD-L5726-
Award Date01/09/2020
Closeout Date04/28/2022
Work DescriptionMAINTENANCE STATION BUILDING WORK.
Location DescriptionSAN BERNARDINO AT THE SAN BERNARDINO MAINTENANCE STATION AT 175 WEST CLUSTER STREET
QA Service Level1 (Verified on 02/26/2020)

Sample Information

Sample Taken Date06/16/2020 Sample Unique Key8
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/22/2020
Sample typeQuality Assurance A brief description of the sampleF1554 Gr 36 anchor bolts
The quantity of what the sample constitutes67 From where was the sample collectedDistributor
First name of sampler or witnessed byChris Last name of sampler or witnessed byDsouza
Title of samplerQA Inspector Telephone number of sampler646-942-3585
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCordova Bolt Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL132-094-20 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)1202008878,3500007821 Nut Mfg. Lot Number(s)434578A
Washer Mfg. Lot Number(s) Bolt SpecificationF1554 Gr 36 anchor bolts
Bolt Length(s)30" Nut SpecificationA563 DH
Washer SpecificationNA Finish
Diameter/Size7/8 Bolt Mfg. Lot Number2005227A 2/3
Rocap Test Requirement(s) Lubricant Requirements(s)

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2020-06-16-8-1ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory06/24/2020bewing
Yes
07/02/2020Nut Proof
2020-06-16-8-2ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory06/24/2020bewing
Yes
07/02/2020Nut Proof
2020-06-16-8-3ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory07/02/2020bewing
Yes
07/02/2020
2020-06-16-8-4ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory07/02/2020Brian Ewing
Yes
07/02/2020
2020-06-16-8-5ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory07/02/2020Brian Ewing
Yes
07/02/2020
2020-06-16-8-6ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory07/02/2020Brian Ewing
Yes
07/02/2020
2020-06-16-8-7ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory07/02/2020Brian Ewing
Yes
07/02/2020
2020-06-16-8-8ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory07/02/2020Brian Ewing
Yes
07/02/2020
2020-06-16-8-9ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory07/02/2020Brian Ewing
Yes
07/02/2020
2020-06-16-8-10ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory07/02/2020Brian Ewing
Yes
07/02/2020

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2020-06-16-8-1 ASTM F606-14a (Verified)
DIME Test ID: 2020-06-16-8-2 ASTM F606-14a (Verified)
DIME Test ID: 2020-06-16-8-3 ASTM A370-15 (Verified)
DIME Test ID: 2020-06-16-8-4 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-06-16-8-5 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-06-16-8-6 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-06-16-8-7 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-06-16-8-8 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-06-16-8-9 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-06-16-8-10 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-06-16-8-11 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-06-16-8-12 ASTM B499-14 (Verified)
DIME Test ID: 2020-06-16-8-13 ASTM B499-14 (Verified)
DIME Test ID: 2020-06-16-8-14 ASTM B499-14 (Verified)
DIME Test ID: 2020-06-16-8-15 ASTM B499-14 (Verified)
DIME Test ID: 2020-06-16-8-16 ASTM B499-14 (Verified)
DIME Test ID: 2020-06-16-8-17 ASTM B499-14 (Verified)
DIME Test ID: 2020-06-16-8-18 ASTM B499-14 (Verified)
DIME Test ID: 2020-06-16-8-19 ASTM B499-14 (Verified)
DIME Test ID: 2020-06-16-8-20 ASTM A370-15 (Verified)