Sample Record
Owner Lab
- CT D08 - Fontana Southern Regional Laboratory
DIME Sample ID 2020-04-13-7
Project Information
Project Identifiers | Project ID: 7613 DEA: 071218W4 EFIS: 0700021119 |
---|---|
DIST-CO-RTE-PM | 07-LA-5-29.4/31.6 |
Award Date | 11/29/2012 |
Closeout Date | 07/31/2023 |
Work Description | REALIGN ROUTE 5 AND RAILROAD TRACKS AND RECONFIGURE ON- AND OFF-RAMPS. |
Location Description | LOS ANGELES COUNTY IN BURBANK FROM WEST MAGNOLIA BOULEVARD OVERCROSSING TO 0.3 MILE NORTH OF BUENA VISTA STREET/WINONA AVENUE UNDERCROSSING |
QA Service Level | 1 (Verified on 10/08/2012) |
Sample Information
Sample Taken Date | 04/13/2020 | Sample Unique Key | 7 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/14/2020 |
Sample type | Department Acceptance | A brief description of the sample | 1" Aggregate for Acceptance |
The quantity of what the sample constitutes | 1 bag 130 cy | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | MD | Last name of sampler or witnessed by | Shajahan |
Title of sampler | MREA | Telephone number of sampler | |
Laboratory sample identification | 9716 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Source Vulcan Sunvalley, Sampled from Security Paving Burbank | Transportation Laboratory (TL) Number | 94443 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 00-00-0000 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
The plant number | Unknown | A detailed description of where the material sample was collected | Security Paving OnSite |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 1 inch |
The concrete mix design number | G3-16-PCC002 | Lot number | Unknown |
Sublot number | Unknown | Aggregate Mix Number | Not set |
Submitted Tests
DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Submitted By | Verified? | Release Date | Test Comments | Actions |
---|---|---|---|---|---|---|---|---|
2020-04-13-7-1 | CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates | Edmond Jabbour, CT D08 - Fontana Southern Regional Laboratory | 04/16/2020 | Matthew Clayton | No | Info | ||
2020-04-13-7-2 | CTM 227-December 2014: Method of Test for Evaluating Cleanness of Coarse Aggregate (Cleanness) | Larry Diaz, CT D08 - Fontana Southern Regional Laboratory | 04/21/2020 | Matthew Clayton | No | Info |
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2020-04-13-7-1 CTM 202-November 2011
DIME Test ID: 2020-04-13-7-2 CTM 227-December 2014