Owner Lab
- CT HQ - QASI Sacramento Field Office
DIME Sample ID 2020-04-28-2
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 214278 DEA: 060V9104 EFIS: 0617000062 |
DIST-CO-RTE-PM | 06-FRE,KER,KIN,MAD,TUL-5,41,99,184-Var |
Award Date | 09/27/2019 |
Closeout Date | 04/04/2022 |
Work Description | INSTALL ZERO EMISSIONS VEHICLE CHARGING STATIONS. |
Location Description | FRESNO, KERN, KINGS, MADERA, AND TULARE COUNTIES AT VARIOUS LOCATIONS |
QA Service Level | 1 (Verified on 07/29/2019) |
Sample Information
Sample Taken Date | 04/28/2020 |
Sample Unique Key | 2 |
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes |
Date that the sample was received by the laboratory/organization performing the testing | 04/28/2020 |
Sample type | Quality Assurance |
A brief description of the sample | Anchor Bolt Assembly |
The quantity of what the sample constitutes | 1 Anchor Bolt, 8 Hexagonal Nuts, 8 Washers |
From where was the sample collected | Other |
First name of sampler or witnessed by | Nathan |
Last name of sampler or witnessed by | Strid |
Title of sampler | Assistant METS Representative |
Telephone number of sampler | 5593130079 |
Laboratory sample identification | |
Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Portland Bolt |
Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | |
Structure unique identifier | |
Structure name | |
---|
Material Information
Material Type | SMTL TM3 - Fastener Assembly |
Rocap Number(s) | |
Heat Number(s) | A195747 |
Nut Mfg. Lot Number(s) | 32150-190840 |
Washer Mfg. Lot Number(s) | 0120-341 |
Bolt Specification | ASTM F1554 |
Bolt Length(s) | 36" |
Nut Specification | ASTM A563 |
Washer Specification | ASTM F436 |
Finish | Hot Dip Galv |
Diameter/Size | 1" |
Bolt Mfg. Lot Number | 348912 |
Rocap Test Requirement(s) | |
Lubricant Requirements(s) | |
Submitted Tests
DIME Test ID | Test Method | Tester Name | Testing Lab | Date Tested | Submitted By | Verified? | Release Date | Test Comments | Actions |
2020-04-28-2-1 | ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load) | fsaylor | CT HQ - Sacramento Structural Materials Testing Laboratory | 04/29/2020 | fsaylor | Yes | 04/30/2020 | Proof Load | |
2020-04-28-2-2 | ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter) | Fred Saylor | CT HQ - Sacramento Structural Materials Testing Laboratory | 04/29/2020 | Fred Saylor | Yes | 04/30/2020 | | |
2020-04-28-2-3 | ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating) | Fred Saylor | CT HQ - Sacramento Structural Materials Testing Laboratory | 04/29/2020 | Fred Saylor | Yes | 04/30/2020 | | |
2020-04-28-2-4 | ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating) | Fred Saylor | CT HQ - Sacramento Structural Materials Testing Laboratory | 04/29/2020 | Fred Saylor | Yes | 04/30/2020 | | |
2020-04-28-2-5 | ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating) | Fred Saylor | CT HQ - Sacramento Structural Materials Testing Laboratory | 04/29/2020 | Fred Saylor | Yes | 04/30/2020 | | |
2020-04-28-2-6 | ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating) | Fred Saylor | CT HQ - Sacramento Structural Materials Testing Laboratory | 04/29/2020 | Fred Saylor | Yes | 04/30/2020 | | |
2020-04-28-2-7 | ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating) | Fred Saylor | CT HQ - Sacramento Structural Materials Testing Laboratory | 04/29/2020 | Fred Saylor | Yes | 04/30/2020 | | |
2020-04-28-2-8 | ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating) | Fred Saylor | CT HQ - Sacramento Structural Materials Testing Laboratory | 04/29/2020 | Fred Saylor | Yes | 04/30/2020 | | |
2020-04-28-2-9 | ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating) | Fred Saylor | CT HQ - Sacramento Structural Materials Testing Laboratory | 04/29/2020 | Fred Saylor | Yes | 04/30/2020 | | |
2020-04-28-2-10 | ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness) | Fred Saylor | CT HQ - Sacramento Structural Materials Testing Laboratory | 04/29/2020 | Fred Saylor | Yes | 04/30/2020 | | |
80971809728097380974809758097680977809788097980980
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
No results found. |
Test File Attachments
DIME Test ID: 2020-04-28-2-1 ASTM F606-14a (Verified)
DIME Test ID: 2020-04-28-2-2 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-04-28-2-3 ASTM B499-14 (Verified)
DIME Test ID: 2020-04-28-2-4 ASTM B499-14 (Verified)
DIME Test ID: 2020-04-28-2-5 ASTM B499-14 (Verified)
DIME Test ID: 2020-04-28-2-6 ASTM B499-14 (Verified)
DIME Test ID: 2020-04-28-2-7 ASTM B499-14 (Verified)
DIME Test ID: 2020-04-28-2-8 ASTM B499-14 (Verified)
DIME Test ID: 2020-04-28-2-9 ASTM B499-14 (Verified)
DIME Test ID: 2020-04-28-2-10 ASTM E18-15 (Verified)
DIME Test ID: 2020-04-28-2-11 ASTM E18-15 (Verified)
DIME Test ID: 2020-04-28-2-12 ASTM A370-15 (Verified)
DIME Test ID: 2020-04-28-2-13 ASTM A370-15 (Verified)