Sample Record

Owner Lab

  • CT - Unassigned/General Field Laboratory

DIME Sample ID 2020-03-13-14

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214817
DEA: 051H2304
EFIS: 0516000042
DIST-CO-RTE-PM05-MON-218-R0.2/L0.9
Award Date11/08/2022
Closeout DateNot set
Work DescriptionCONSTRUCT CURB RAMPS AND SIDEWALK, MODIFY SIGNAL AND LIGHTING SYSTEMS.
Location DescriptionMONTEREY COUNTY IN SEASIDE FROM DEL MONTE BOULEVARD TO FREMONT BOULEVARD
QA Service Level1 (Verified on 08/31/2020)

Sample Information

Sample Taken Date03/13/2020 Sample Unique Key14
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/16/2020
Sample typePreliminary A brief description of the sampleNative Soil
The quantity of what the sample constitutes1 bag From where was the sample collectedJob Site
First name of sampler or witnessed byJacob Last name of sampler or witnessed byBerven
Title of sampler Telephone number of sampler
Laboratory sample identification20-D-013 Linked DIME Sample ID
The fabricator/manufacturer/facility nameEarth Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sampleUnknown
The fabricator/manufacturer designation for the sampleUnknown A detailed description of where the material sample was collectedWB Shoulder L 0.45
Where the material sample would have been placed if not sampledUnknown

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2020-03-13-14-1CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse AggregatesDaniel Gingras, CT D05 - San Luis Obispo District Laboratory03/23/2020Daniel Gingras
Yes
04/01/2020
2020-03-13-14-2CTM 301-March 2000: Method for Determining the Resistance "R" Value of Treated and Untreated Bases, Subbases, and Basement Soils by the StabilometerDaniel Gingras, CT D05 - San Luis Obispo District Laboratory04/01/2020Daniel Gingras
Yes
04/01/2020
2020-03-13-14-3CTM 204-June 2010: Method of Test for Liquid Limit, Plastic Limit and Plasticity Index of Soils (Plasticity Index)E. Atkins, CT D05 - San Luis Obispo District Laboratory03/24/2020Daniel Gingras
Yes
04/01/2020Liquid Limit could not be determined due to sliding in cup. (Note in CTM 204, Part I, 1.b., 2., c.)

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2020-03-13-14-1 CTM 202-November 2011 (Verified)
DIME Test ID: 2020-03-13-14-2 CTM 301-March 2000 (Verified)
DIME Test ID: 2020-03-13-14-3 CTM 204-June 2010 (Verified)