Sample Record

Owner Lab

  • CT D08 - Fontana Southern Regional Laboratory

DIME Sample ID 2019-10-07-27

Project Information

Project IdentifiersProject ID: 214670
DEA: 07331004
EFIS: 0716000220
DIST-CO-RTE-PM07-VEN-101-9.0/9.2
Award Date04/13/2022
Closeout DateNot set
Work DescriptionCONCRETE SLAB REPLACEMENT & GRIND, PAVEMENT & RESURFACE ACE
Location DescriptionVENTURA COUNTY IN THOUSAND OAKS FROM NORTHBOUND OFF-RAMP TO SOUTHBOUND OFF-RAMP AT CONEJO COMMERCIAL VEHICLE ENFORCEMENT FACILITIES
QA Service Level1 (Verified on 07/12/2021)

Sample Information

Sample Taken Date10/07/2019 Sample Unique Key27
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/09/2019
Sample typePreliminary A brief description of the samplenative soil sample 3'
The quantity of what the sample constitutes1 bag From where was the sample collectedJob Site
First name of sampler or witnessed byJOSE Last name of sampler or witnessed byMENDEZ
Title of samplerTET Telephone number of sampler
Laboratory sample identification8759 Linked DIME Sample ID2019-10-07-27
The fabricator/manufacturer/facility nameNone Transportation Laboratory (TL) NumberC989226
Inspector Lot Number from the Transportation Laboratory (TL) FormSAMPLE 3 RTE NB101 PM 9 Structure unique identifier
Structure nameCONEJO WIM FACILITY NB

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sampleUnknown
The fabricator/manufacturer designation for the sampleUnknown A detailed description of where the material sample was collectedRTE 101NB PM 9.0 RT SHLD MID POINT TOP
Where the material sample would have been placed if not sampledUnknown

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2019-10-07-27-1CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse AggregatesLARRY DIAZ, CT D08 - Fontana Southern Regional Laboratory10/14/2019Jose Mendez
No
Info
2019-10-07-27-2CTM 301-March 2000: Method for Determining the Resistance "R" Value of Treated and Untreated Bases, Subbases, and Basement Soils by the StabilometerKIET PHAN, CT D08 - Fontana Southern Regional Laboratory10/17/2019Jose Mendez
No
Info

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2019-10-07-27-1 CTM 202-November 2011
DIME Test ID: 2019-10-07-27-2 CTM 301-March 2000