Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2020-01-22-17

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 213688
DEA: 044H0804
EFIS: 0413000097
DIST-CO-RTE-PM04-ALA-238,580-VAR
Award Date12/13/2018
Closeout Date06/15/2020
Work DescriptionPLACE TEMP SUPPORT, BR REMOVAL, RSC BRIDGE AND MISC METAL.
Location DescriptionALAMEDA COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 02/13/2019)

Sample Information

Sample Taken Date01/22/2020 Sample Unique Key17
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/23/2020
Sample typeQuality Assurance A brief description of the sampleCoupler
The quantity of what the sample constitutes4 From where was the sample collectedFabricator
First name of sampler or witnessed bySean Last name of sampler or witnessed byskeen
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility namenVent Products Transportation Laboratory (TL) NumberC759532
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerErico Intermediate Assembler or FabricatorUnknown
Rebar Size4 Coupler ModelLenton Formsavers
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)L9143 Rebar Heat Number(s)3500009272, 3500005956
Rebar Size 2 Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2020-01-22-17-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory01/24/2020bewing
Yes
01/27/2020Service Splice
2020-01-22-17-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory01/24/2020bewing
Yes
01/27/2020Service Splice
2020-01-22-17-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory01/24/2020bewing
Yes
01/27/2020Service Splice

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2020-01-22-17-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2020-01-22-17-2 CTM 670-December 2013 (Verified)