Sample Record
Owner Lab
- CT D08 - Fontana Southern Regional Laboratory
DIME Sample ID 2019-11-18-4
Project Information
Project Identifiers | Project ID: 214216 DEA: 071XM404 EFIS: 0719000232 |
---|---|
DIST-CO-RTE-PM | 07-VEN-33-22.16, 22.16 |
Award Date | 06/21/2019 |
Closeout Date | 10/06/2022 |
Work Description | This is the emergency project to repair pavement cracking, stabilize the eroded slope, construct a soldier pile tieback wall and reconstruct the steel post MGS |
Location Description | Ventura County on Route 33 at PM.22.16. |
QA Service Level | 1 (Verified on 08/27/2019) |
Sample Information
Sample Taken Date | 11/18/2019 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/20/2019 |
Sample type | Quality Assurance | A brief description of the sample | Native Soil |
The quantity of what the sample constitutes | 2 bags | From where was the sample collected | Job Site |
First name of sampler or witnessed by | JOSE | Last name of sampler or witnessed by | GUZMAN |
Title of sampler | MREA | Telephone number of sampler | |
Laboratory sample identification | 8896 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Native Material | Transportation Laboratory (TL) Number | C394112 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | STOCK PILE PM 22 13 | Structure unique identifier | |
Structure name |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Unknown |
---|---|---|---|
The fabricator/manufacturer designation for the sample | Unknown | A detailed description of where the material sample was collected | STOCKPILE PM 22.13 |
Where the material sample would have been placed if not sampled | Unknown |
Submitted Tests
DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Submitted By | Verified? | Release Date | Test Comments | Actions |
---|---|---|---|---|---|---|---|---|
2019-11-18-4-6 | CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates | JUAN A LE ROY, CT D08 - Fontana Southern Regional Laboratory | 11/20/2019 | Jose Mendez | No | Info | ||
2019-11-18-4-7 | CTM 204-June 2010: Method of Test for Liquid Limit, Plastic Limit and Plasticity Index of Soils (Plasticity Index) | TESS PEREZ, CT D08 - Fontana Southern Regional Laboratory | 11/21/2019 | Jose Mendez | No | Info | ||
2019-11-18-4-8 | CTM 217-June 2011: Method of Test for Sand Equivalent | JUAN A LE ROY, CT D08 - Fontana Southern Regional Laboratory | 11/20/2019 | Jose Mendez | No | Info | ||
2019-11-18-4-9 | CTM 301-March 2000: Method for Determining the Resistance "R" Value of Treated and Untreated Bases, Subbases, and Basement Soils by the Stabilometer | KIET PHAN, CT D08 - Fontana Southern Regional Laboratory | 11/21/2019 | Jose Mendez | No | Info | ||
2019-11-18-4-10 | ASTM D4829-11: Standard Test Method for Expansion Index of Soils | MICHEAL MAGANA, CT D08 - Fontana Southern Regional Laboratory | 11/20/2019 | Jose Mendez | No | VERY LOW | Info |
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2019-11-18-4-6 CTM 202-November 2011
DIME Test ID: 2019-11-18-4-7 CTM 204-June 2010
DIME Test ID: 2019-11-18-4-8 CTM 217-June 2011
DIME Test ID: 2019-11-18-4-9 CTM 301-March 2000
DIME Test ID: 2019-11-18-4-10 ASTM D4829-11