Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
DIME Sample ID 2019-10-07-11
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 214077 DEA: 101C5304 EFIS: 1015000002 |
DIST-CO-RTE-PM | 10-STA,SJ-5,99-Var |
Award Date | 05/24/2019 |
Closeout Date | 04/26/2021 |
Work Description | OVERHEAD AND ROADSIDE SIGNS, AND MODIFY ELECTRICAL SYSTEMS. |
Location Description | SAN JOAQUIN AND STANISLAUS COUNTIES AT VARIOUS LOCATIONS |
QA Service Level | 1 (Verified on 04/11/2019) |
Sample Information
Sample Taken Date | 10/07/2019 |
Sample Unique Key | 11 |
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes |
Date that the sample was received by the laboratory/organization performing the testing | 10/16/2019 |
Sample type | Quality Assurance |
A brief description of the sample | 2.5" x 5' F1554 Gr 55 anchor bolt assembly |
The quantity of what the sample constitutes | 64 assemblies |
From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Greg |
Last name of sampler or witnessed by | Thompson |
Title of sampler | Associate Steel Inspector |
Telephone number of sampler | 510-376-7155 |
Laboratory sample identification | |
Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Edsco Fasteners |
Transportation Laboratory (TL) Number | C835654 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B9-105-19 |
Structure unique identifier | |
Structure name | |
---|
Material Information
Material Type | SMTL TM3 - Fastener Assembly |
Rocap Number(s) | |
Heat Number(s) | 178035 A164716 196635 |
Nut Mfg. Lot Number(s) | 66104 / W3023
84073 / W6631 |
Washer Mfg. Lot Number(s) | 316808 |
Bolt Specification | F1554 gr 55 |
Bolt Length(s) | 5' |
Nut Specification | A194 gr2H/DH Heavy Hex |
Washer Specification | F436 |
Finish | Plain and HDG |
Diameter/Size | 2.5" |
Bolt Mfg. Lot Number | |
Rocap Test Requirement(s) | |
Lubricant Requirements(s) | |
Submitted Tests
DIME Test ID | Test Method | Tester Name | Testing Lab | Date Tested | Submitted By | Verified? | Release Date | Test Comments | Actions |
2019-10-07-11-11 | ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage) | Rheanna Andelin | CT HQ - Sacramento Structural Materials Testing Laboratory | 10/18/2019 | Rheanna Andelin | Yes | 10/18/2019 | | |
2019-10-07-11-12 | ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating) | Rheanna Andelin | CT HQ - Sacramento Structural Materials Testing Laboratory | 10/18/2019 | Rheanna Andelin | Yes | 10/18/2019 | | |
2019-10-07-11-13 | ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating) | Rheanna Andelin | CT HQ - Sacramento Structural Materials Testing Laboratory | 10/18/2019 | Rheanna Andelin | Yes | 10/18/2019 | | |
2019-10-07-11-14 | ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating) | Rheanna Andelin | CT HQ - Sacramento Structural Materials Testing Laboratory | 10/18/2019 | Rheanna Andelin | Yes | 10/18/2019 | | |
2019-10-07-11-15 | ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating) | Rheanna Andelin | CT HQ - Sacramento Structural Materials Testing Laboratory | 10/18/2019 | Rheanna Andelin | Yes | 10/18/2019 | | |
2019-10-07-11-16 | ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating) | Rheanna Andelin | CT HQ - Sacramento Structural Materials Testing Laboratory | 10/18/2019 | Rheanna Andelin | Yes | 10/18/2019 | | |
2019-10-07-11-17 | ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating) | Rheanna Andelin | CT HQ - Sacramento Structural Materials Testing Laboratory | 10/18/2019 | Rheanna Andelin | Yes | 10/18/2019 | | |
2019-10-07-11-18 | ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating) | Rheanna Andelin | CT HQ - Sacramento Structural Materials Testing Laboratory | 10/18/2019 | Rheanna Andelin | Yes | 10/18/2019 | | |
2019-10-07-11-19 | ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating) | Rheanna Andelin | CT HQ - Sacramento Structural Materials Testing Laboratory | 10/18/2019 | Rheanna Andelin | Yes | 10/18/2019 | | |
2019-10-07-11-20 | ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating) | Rheanna Andelin | CT HQ - Sacramento Structural Materials Testing Laboratory | 10/18/2019 | Rheanna Andelin | Yes | 10/18/2019 | | |
70281702827028370284702867028770288702907029170292