Sample Record
Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
DIME Sample ID 2019-09-06-7
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 212899 DEA: 051C6704 EFIS: 0512000194 |
---|---|
DIST-CO-RTE-PM | 05-SCR-17-0.2-0.5 |
Award Date | 02/08/2019 |
Closeout Date | 09/23/2022 |
Work Description | PASATIEMPO RETAINING WALL - |
Location Description | IN SANTA CRUZ FROM 0.5 MILE TO 0.3 MILES SOUTH OF PASATIEMPO OVERCROSSING |
QA Service Level | 1 (Verified on 04/01/2019) |
Sample Information
Sample Taken Date | 09/06/2019 | Sample Unique Key | 7 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/12/2019 |
Sample type | Quality Assurance | A brief description of the sample | # 8 ASTM Gr. 80 Threaded Bar |
The quantity of what the sample constitutes | 126 ea | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Ed | Last name of sampler or witnessed by | Fleming |
Title of sampler | TET | Telephone number of sampler | 707-310-2029 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Stressteel | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B10-185-19 | Structure unique identifier | 44-SCR |
Structure name |
Material Information
Material Type | SMTL TM5 - Threaded Bar | Production or Authorization Testing | Production Testing |
---|---|---|---|
Threaded Bar Specification | ASTM A615 | Threaded Bar Grade | 80 |
Threaded Bar Type | Plain | Rebar Size | |
Nut Specification for Threaded Bar | Grade 75 | System Manufacturer | Stresssteel |
Epoxy Coating Color | NA | Threaded Bar Application | Soil Nail |
Coating Standards | Uncoated | Bar Heat Number(s) | 3700001011 |
Nut Heat Number(s) | 100889956-01 | Bar Lot Number | 370000101120 |
Nut Lot Number | 4774 | Coupler Heat Number(s) | Unknown |
Coupler Grade | Unknown |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2019-09-06-7-1 ASTM A615-15 (Verified)
DIME Test ID: 2019-09-06-7-2 ASTM A615-15 (Verified)
DIME Test ID: 2019-09-06-7-3 ASTM A615-15 (Verified)