Sample Record

Owner Lab

  • CT D08 - Fontana Southern Regional Laboratory

DIME Sample ID 2019-07-22-18

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214000
DEA: 073W8604
EFIS: 0717000117
DIST-CO-RTE-PM07-LA-1-35.3/46.9
Award Date05/01/2019
Closeout Date06/05/2020
Work DescriptionAPPLY SLURRY SEAL TO ROADWAY.
Location DescriptionLOS ANGELES COUNTY IN SANTA MONICA AND MALIBU FROM 0.3 MILE SOUTH OF PALISADE PEDESTRIAN OVERCROSSING TO MALIBU LAGOON BRIDGE
QA Service Level1 (Verified on 07/26/2019)

Sample Information

Sample Taken Date07/22/2019 Sample Unique Key18
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/31/2019
Sample typeVerification A brief description of the sample3/4 HMA-A-SP R15
The quantity of what the sample constitutesPSE 5 Buckets From where was the sample collectedManufacturer
First name of sampler or witnessed byAll American Asphalt Irwindale Last name of sampler or witnessed byQC
Title of sampler Telephone number of sampler
Laboratory sample identification0455A-19 Linked DIME Sample ID
The fabricator/manufacturer/facility nameAll American Asphalt Corona Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0005::ALL AMERICAN ASPHALT
The fabricator's/manufacturer's product name for the sample3/4 HMA-A-SP R15 The fabricator/manufacturer designation for the sample105793
The plant numberUnknown A detailed description of where the material sample was collectedBelt Cut at All American Irwindale Plant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2019-07-22-18-1AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)Sebastian Ferrer, CT D08 - Fontana Southern Regional Laboratory08/01/2019Michael Magana
Yes
08/22/2019
2019-07-22-18-2AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)Satish Jain, CT D08 - Fontana Southern Regional Laboratory08/06/2019Michael Magana
Yes
08/22/2019
2019-07-22-18-3AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)Larry Diaz, CT D08 - Fontana Southern Regional Laboratory08/02/2019Michael Magana
Yes
08/22/2019
2019-07-22-18-4AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)Sebstian Ferrer, CT D08 - Fontana Southern Regional Laboratory08/01/2019Michael Magana
Yes
08/22/2019
2019-07-22-18-5AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)Sebastian Ferrer, CT D08 - Fontana Southern Regional Laboratory08/02/2019Michael Magana
Yes
08/22/2019
2019-07-22-18-6AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)Sebastian Ferrer, CT D08 - Fontana Southern Regional Laboratory08/02/2019Michael Magana
Yes
08/22/2019
2019-07-22-18-7ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)Satish Jain, CT D08 - Fontana Southern Regional Laboratory08/06/2019Michael Magana
Yes
08/22/2019
2019-07-22-18-8AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)Satish Jain, CT D08 - Fontana Southern Regional Laboratory08/06/2019Michael Magana
Yes
08/22/2019
2019-07-22-18-9CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse AggregatesJose Guzman, CT D08 - Fontana Southern Regional Laboratory08/05/2019Michael Magana
Yes
08/22/2019RAP Gradation After Ignition Oven
2019-07-22-18-10CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse AggregatesSebastian Ferrer, CT D08 - Fontana Southern Regional Laboratory08/01/2019Michael Magana
Yes
08/22/2019Combined Virgin Aggregate/RAP Gradation w/Correlation Factors Applied

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2019-07-22-18-1 AASHTO T27-14 (Verified)
DIME Test ID: 2019-07-22-18-2 AASHTO T335-09r13 (Verified)
DIME Test ID: 2019-07-22-18-3 AASHTO T85-13 (Verified)
DIME Test ID: 2019-07-22-18-4 AASHTO T84-14 (Verified)
DIME Test ID: 2019-07-22-18-5 AASHTO T96-02r10 (Verified)
DIME Test ID: 2019-07-22-18-6 AASHTO T176-08 (Verified)
DIME Test ID: 2019-07-22-18-7 ASTM D4791-10 (Verified)
DIME Test ID: 2019-07-22-18-8 AASHTO T304-11 (Verified)
DIME Test ID: 2019-07-22-18-9 CTM 202-November 2011 (Verified)
DIME Test ID: 2019-07-22-18-10 CTM 202-November 2011 (Verified)