Sample Record
Owner Lab
- CT HQ - Sacramento Cement Testing Laboratory
DIME Sample ID 2019-07-26-4
Project Information
Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 07/26/2019 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/26/2019 |
Sample type | Annual Source Testing | A brief description of the sample | Type II/IV |
The quantity of what the sample constitutes | 1 Bucket | From where was the sample collected | Source |
First name of sampler or witnessed by | Unknown | Last name of sampler or witnessed by | Unknown |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | CM195929 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Cal Portland | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Cementitious | Brand | Cal Portland |
---|---|---|---|
Mill | Rillito Type II V Extra | Type of Cementitious Material | Type II/V Cement |
Submitted Tests
DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Submitted By | Verified? | Release Date | Test Comments | Actions |
---|---|---|---|---|---|---|---|---|
2019-07-26-4-2 | ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens) | Spencer Adams, CT HQ - Sacramento Cement Testing Laboratory | 08/16/2019 | Spencer Adams | No | Info | ||
2019-07-26-4-3 | ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens) | Spencer Adams, CT HQ - Sacramento Cement Testing Laboratory | 08/20/2019 | Spencer Adams | No | Info | ||
2019-07-26-4-4 | ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens) | Spencer Adams, CT HQ - Sacramento Cement Testing Laboratory | 09/10/2019 | Spencer Adams | No | Info | ||
2019-07-26-4-5 | ASTM C185-15a: Standard Test Method for Air Content of Hydraulic Cement Mortar | Stephen Donnelly, CT HQ - Sacramento Cement Testing Laboratory | 08/26/2019 | Stephen Donnelly | No | Info | ||
2019-07-26-4-6 | ASTM C191-13: Standard Test Methods for Time of Setting of Hydraulic Cement by Vicat Needle | Stephen Donnelly, CT HQ - Sacramento Cement Testing Laboratory | 09/06/2019 | Stephen Donnelly | No | Info | ||
2019-07-26-4-7 | ASTM C204-11: Standard Test Methods for Fineness of Hydraulic Cement by Air-Permeability Apparatus | Stephen Donnelly, CT HQ - Sacramento Cement Testing Laboratory | 07/31/2019 | Stephen Donnelly | No | Info |
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2019-07-26-4-2 ASTM C109-16a
DIME Test ID: 2019-07-26-4-3 ASTM C109-16a
DIME Test ID: 2019-07-26-4-4 ASTM C109-16a
DIME Test ID: 2019-07-26-4-5 ASTM C185-15a
DIME Test ID: 2019-07-26-4-6 ASTM C191-13
DIME Test ID: 2019-07-26-4-7 ASTM C204-11