Sample Record
Owner Lab
- CT D08 - Fontana Southern Regional Laboratory
DIME Sample ID 2019-07-12-4
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 213764 DEA: 080F0304 EFIS: 0800020358 |
---|---|
DIST-CO-RTE-PM | 08-SBD-60-R0.7/R3.0 |
Award Date | 03/07/2019 |
Closeout Date | 07/27/2023 |
Work Description | REMOVE AND REPLACE THREE OVERCROSSING BRIDGES ON ROUTE 60 |
Location Description | IN SAN BERNARDINO COUNTY IN AND NEAR CHINO AT VARIOUS LOCATIONS FROM O.1 MILE WEST OF PIPELINE AVENUE OVERCROSSING TO 0.1 MILE EAST OF BENSON AVENUE OVERCROSSING |
QA Service Level | 1 (Verified on 05/01/2019) |
Sample Information
Sample Taken Date | 07/12/2019 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/17/2019 |
Sample type | Verification | A brief description of the sample | 3/4 HMA-A-SP R15 |
The quantity of what the sample constitutes | JMF 6 bags | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | RJ Noble Corona | Last name of sampler or witnessed by | QC |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 0420A-19 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Chanders Aggregates, Mayhew Aggregates | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-33-0014, 91-33-0039 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | 3/4 HMA-A-SP R15 | The fabricator/manufacturer designation for the sample | 36R1504SPWC |
The plant number | Unknown | A detailed description of where the material sample was collected | Belt Cut at RJ Noble Corona Plant |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 3/4 inch |
The concrete mix design number | Unknown | Lot number | Unknown |
Sublot number | Unknown | Aggregate Mix Number | Not set |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2019-07-12-4-1 AASHTO T27-14 (Verified)
DIME Test ID: 2019-07-12-4-2 AASHTO T335-09r13 (Verified)
DIME Test ID: 2019-07-12-4-3 AASHTO T85-13 (Verified)
DIME Test ID: 2019-07-12-4-4 AASHTO T84-14 (Verified)
DIME Test ID: 2019-07-12-4-5 AASHTO T96-02r10 (Verified)
DIME Test ID: 2019-07-12-4-6 AASHTO T176-08 (Verified)
DIME Test ID: 2019-07-12-4-7 ASTM D4791-10 (Verified)
DIME Test ID: 2019-07-12-4-8 AASHTO T304-11 (Verified)
DIME Test ID: 2019-07-12-4-9 CTM 202-November 2011 (Verified)
DIME Test ID: 2019-07-12-4-10 CTM 202-November 2011 (Verified)