Sample Record

Owner Lab

  • CT HQ - QASI Los Angeles Field Office

DIME Sample ID 2019-07-02-16

Project Information

Project Identifiers
DEA: No Project
DIST-CO-RTE-PM---
Award DateNot set
Closeout Date11/01/2022
Work DescriptionSpecial project identifier for material not associated with a project
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date07/02/2019 Sample Unique Key16
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing07/09/2019
Sample typeQuality Assurance A brief description of the sample7/8" x 17.5" A449 Bolts HDG
The quantity of what the sample constitutes12 From where was the sample collectedFabricator
First name of sampler or witnessed byArthur Last name of sampler or witnessed byPeterson
Title of samplerQA Inspector Telephone number of sampler707-342-8602
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameUIS Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL110-087-19 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)190043 Nut Mfg. Lot Number(s)
Washer Mfg. Lot Number(s) Bolt SpecificationNA
Bolt Length(s) Nut SpecificationNA
Washer SpecificationNA FinishHDG
Diameter/Size7/8" x 17.5" Bolt Mfg. Lot Number32036
Rocap Test Requirement(s) Lubricant Requirements(s)

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2019-07-02-16-1ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)Steve, CT HQ - Sacramento Structural Materials Testing Laboratory07/15/2019Steve
Yes
07/23/2019Head Popped Off
2019-07-02-16-2ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)Steve, CT HQ - Sacramento Structural Materials Testing Laboratory07/15/2019Steve
Yes
07/23/2019Head Popped off
2019-07-02-16-3ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)Steve, CT HQ - Sacramento Structural Materials Testing Laboratory07/15/2019Steve
Yes
07/23/2019Stripped Out
2019-07-02-16-4ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)Steve, CT HQ - Sacramento Structural Materials Testing Laboratory07/15/2019Steve
Yes
07/23/2019Head Popped Off
2019-07-02-16-5ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)Steve, CT HQ - Sacramento Structural Materials Testing Laboratory07/15/2019Steve
Yes
07/23/2019Head Popped Off
2019-07-02-16-6ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory07/16/2019Steven Paine
Yes
07/23/2019
2019-07-02-16-7ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory07/16/2019Steven Paine
Yes
07/23/2019
2019-07-02-16-8ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory07/16/2019Steven Paine
Yes
07/23/2019
2019-07-02-16-9ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory07/16/2019Steven Paine
Yes
07/23/2019
2019-07-02-16-10ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory07/16/2019Steven Paine
Yes
07/23/2019

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2019-07-02-16-1 ASTM F606-14 (Verified)
DIME Test ID: 2019-07-02-16-2 ASTM F606-14 (Verified)
DIME Test ID: 2019-07-02-16-3 ASTM F606-14 (Verified)
DIME Test ID: 2019-07-02-16-4 ASTM F606-14 (Verified)
DIME Test ID: 2019-07-02-16-5 ASTM F606-14 (Verified)
DIME Test ID: 2019-07-02-16-6 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-07-02-16-7 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-07-02-16-8 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-07-02-16-9 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-07-02-16-10 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-07-02-16-11 ASTM B499-14 (Verified)
DIME Test ID: 2019-07-02-16-12 ASTM B499-14 (Verified)
DIME Test ID: 2019-07-02-16-13 ASTM B499-14 (Verified)
DIME Test ID: 2019-07-02-16-14 ASTM B499-14 (Verified)
DIME Test ID: 2019-07-02-16-15 ASTM B499-14 (Verified)