Sample Record

Owner Labs

  • Kwik Bond Polymers
  • CT HQ - Sacramento Concrete Testing Laboratory

DIME Sample ID 2019-06-10-1

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 212501
DEA: 022E4804
EFIS: 0200000586
DIST-CO-RTE-PM02-SIS-96,263-103.1/103.6,56.8/57.2
Award Date12/14/2018
Closeout Date12/01/2021
Work DescriptionBRIDGE REPLACEMENT
Location DescriptionSISKIYOU COUNTY ABOUT 8 MILES NORTH OF YREKA ON ROUTE 96 FROM 0.5 MILE WEST TO 0.2 MILE EAST OF ROUTE 263 AND ON ROUTE 263 FROM 0.3 MILE NORTH OF SHASTA RIVER BRIDGE #02-0014 TO ROUTE 96
QA Service Level1 (Verified on 06/06/2017)

Sample Information

Sample Taken Date06/10/2019 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/10/2019
Sample typeQuality Control A brief description of the sample1 gallon can
The quantity of what the sample constitutes36 totes From where was the sample collectedSource
First name of sampler or witnessed byChris Last name of sampler or witnessed byNunes
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameKwik bond and Reichhold Transportation Laboratory (TL) NumberSacramento Caltrans lab
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypePolyester Mfg. Lot Number(s)1188511
Batch number1188511 Mix number1188511

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2019-06-10-1-1ASTM D1475-Nov13: Standard Test Method For Density of Liquid Coatings, Inks, and Related ProductsLarry McCrum, CT HQ - Sacramento Concrete Testing Laboratory07/01/2019Larry McCrum
Yes
07/01/2019
2019-06-10-1-2ASTM D2196-Feb15: Standard Test Methods for Rheological Properties of Non-Newtonian Materials by Rotational ViscometerLarry McCrum, CT HQ - Sacramento Concrete Testing Laboratory07/01/2019Larry McCrum
Yes
07/01/2019
2019-06-10-1-3ASTM D2369-Jul10: Standard Test Method for Volatile Content of CoatingsLarry McCrum, CT HQ - Sacramento Concrete Testing Laboratory07/01/2019Larry McCrum
Yes
07/01/2019
2019-06-10-1-4ASTM D638-Dec14: Standard Test Method for Tensile Properties of PlasticsLarry McCrum, CT HQ - Sacramento Concrete Testing Laboratory07/01/2019Larry McCrum
Yes
07/01/2019Accepted suppliers test results
2019-06-10-1-5CTM 551-August 2012: Method of Test for Determining Suitability of Materials for Overlayment and Repair of Portland Cement Concrete Pavements and StructuresLarry McCrum, CT HQ - Sacramento Concrete Testing Laboratory07/01/2019Larry McCrum
Yes
07/01/2019
2019-06-10-1-6SCAQMD 309-91-Feb93: Determination of Static Volatile EmissionsLarry McCrum, CT HQ - Sacramento Concrete Testing Laboratory07/01/2019Larry McCrum
Yes
07/01/2019

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2019-06-10-1-1 ASTM D1475-Nov13 (Verified)
DIME Test ID: 2019-06-10-1-2 ASTM D2196-Feb15 (Verified)
DIME Test ID: 2019-06-10-1-3 ASTM D2369-Jul10 (Verified)
DIME Test ID: 2019-06-10-1-4 ASTM D638-Dec14 (Verified)
DIME Test ID: 2019-06-10-1-5 CTM 551-August 2012 (Verified)