Sample Record

Owner Lab

  • CT D08 - Fontana Southern Regional Laboratory

DIME Sample ID 2019-05-28-6

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 209695
DEA: 08347704
EFIS: 0800000616
DIST-CO-RTE-PM08-SBD-SR-58-0/12.9
Award Date11/10/2017
Closeout Date01/14/2021
Work Description(Alternative Delivery) The CMGC project will upgrade SR 58 from 2- to 4-lanes in San Bernardino County from the Kern County line to 7.5 miles east of US-395.
Location DescriptionSR-58 / 395 Kramer Junction project. In San Bernardino County from the Kern County line to 7.5 miles east of US-395.
QA Service Level1 (Verified on 12/01/2017)

Sample Information

Sample Taken Date05/28/2019 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/29/2019
Sample typeQuality Assurance A brief description of the sample6x12 concrete cylinders
The quantity of what the sample constitutes2 From where was the sample collectedJob Site
First name of sampler or witnessed byOsman Last name of sampler or witnessed bymohammed
Title of samplerARS Telephone number of sampler
Laboratory sample identification976-20190528 Linked DIME Sample ID
The fabricator/manufacturer/facility nameRobertsons LUCERNE Transportation Laboratory (TL) Number20190528
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameBR 54 1326R Abut 1R ,RW

Material Information

Material TypeConcrete The concrete mix design numberSC675B38
The truck number from where the sample was collected1700 The batch plant ticket number from where the sample was collected6097611
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleSECURITY PAVING
A detailed description of where the material sample was collectedBR 54 1326R Abut 1R RW Where the material sample would have been placed if not sampledBR 54 13226R Abut 1R RW
From Lot No.Unknown Bag Lot No.Unknown

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2019-05-28-6-1ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensMM, CT D08 - Fontana Southern Regional Laboratory06/25/2019Minh Pham
Yes
06/26/2019

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2019-05-28-6-1 ASTM C39-10 (Verified)