Sample Record

Owner Lab

  • CT HQ - Sacramento Hot Mix Asphalt Laboratory

DIME Sample ID 2017-04-03-9

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 213793
DEA: 060W7004
EFIS: 0617000283
DIST-CO-RTE-PM06-FRE-33-24.3/R29.0,R39.9/44.5
Award Date01/24/2019
Closeout Date08/20/2021
Work DescriptionCOLD PLANE AC PAVEMENT, PLACE HMA RESURFACING.
Location DescriptionFRESNO COUNTY ABOUT 7.8 MILES NORTH OF COALINGA FROM NORTH JUNCTION ROUTE 198 TO SOUTH JUNCTION ROUTE 33/5 AND FROM 0.1 MILE NORTH OF NORTH JUNCTION ROUTE 33/5 TO EL PROGRESSIO ROAD
QA Service Level1 (Verified on 01/09/2019)

Sample Information

Sample Taken Date04/03/2017 Sample Unique Key9
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/03/2017
Sample typeQuality Control A brief description of the sampleCombined 1/2 inch Type A untreated (Dispute Resolution)
The quantity of what the sample constitutesJMF HMA Design Data (Dispute Resolution) From where was the sample collectedSource
First name of sampler or witnessed bySPM Last name of sampler or witnessed byAvenal
Title of samplerNA Telephone number of sampler805-473-3016
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameSPM-Avenal Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-10-0006::AVENAL AGGREGATES
The fabricator's/manufacturer's product name for the sampleSPM-Avenal The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedPlant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1/2 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

JMF Information

HMA Design IDJMF3512-2019-97-17-137 Date Created05/01/2019
SubmittalJMF3511-208-2019-83 Submittal Rejected For Use| JMF3513-2019-82

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2017-04-03-9-1AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)G3 Quality, Inc., CT HQ - Sacramento Hot Mix Asphalt Laboratory04/03/2017Clinton Edmiston
Yes
05/08/2019JMF Renewal Dispute Resolution - HQ is handling the dispute by performing a full JMF verifcation through the Aggregate and HMA Labs. JMF served Project ID: 0617000283.
2017-04-03-9-2AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)G3 Quality, Inc., CT HQ - Sacramento Hot Mix Asphalt Laboratory04/03/2017Clinton Edmiston
Yes
05/08/2019JMF Renewal Dispute Resolution - HQ is handling the dispute by performing a full JMF verifcation through the Aggregate and HMA Labs. JMF served Project ID: 0617000283.
2017-04-03-9-3AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)G3 Quality, Inc., CT HQ - Sacramento Hot Mix Asphalt Laboratory04/03/2017Clinton Edmiston
Yes
05/08/2019JMF Renewal Dispute Resolution - HQ is handling the dispute by performing a full JMF verifcation through the Aggregate and HMA Labs. JMF served Project ID: 0617000283.
2017-04-03-9-4AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)G3 Quality, Inc., CT HQ - Sacramento Hot Mix Asphalt Laboratory04/03/2017Clinton Edmiston
Yes
05/08/2019JMF Renewal Dispute Resolution - HQ is handling the dispute by performing a full JMF verifcation through the Aggregate and HMA Labs. JMF served Project ID: 0617000283.
2017-04-03-9-5ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)G3 Quality, Inc., CT HQ - Sacramento Hot Mix Asphalt Laboratory04/03/2017Clinton Edmiston
Yes
05/08/2019JMF Renewal Dispute Resolution - HQ is handling the dispute by performing a full JMF verifcation through the Aggregate and HMA Labs. JMF served Project ID: 0617000283.
2017-04-03-9-6CTM 204-June 2010: Method of Test for Liquid Limit, Plastic Limit and Plasticity Index of Soils (Plasticity Index)G3 Quality, Inc., CT HQ - Sacramento Hot Mix Asphalt Laboratory04/03/2017Clinton Edmiston
Yes
05/08/2019JMF Renewal Dispute Resolution - HQ is handling the dispute by performing a full JMF verifcation through the Aggregate and HMA Labs. JMF served Project ID: 0617000283.
2017-04-03-9-7AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)G3 Quality, Inc., CT HQ - Sacramento Hot Mix Asphalt Laboratory04/03/2017Clinton Edmiston
Yes
05/08/2019JMF Renewal Dispute Resolution - HQ is handling the dispute by performing a full JMF verifcation through the Aggregate and HMA Labs. JMF served Project ID: 0617000283.
2017-04-03-9-8AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)G3 Quality, Inc., CT HQ - Sacramento Hot Mix Asphalt Laboratory04/03/2017Clinton Edmiston
Yes
05/08/2019JMF Renewal Dispute Resolution - HQ is handling the dispute by performing a full JMF verifcation through the Aggregate and HMA Labs. JMF served Project ID: 0617000283.

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-04-03-9-1 AASHTO T335-09r13 (Verified)
DIME Test ID: 2017-04-03-9-2 AASHTO T96-02r10 (Verified)
DIME Test ID: 2017-04-03-9-3 AASHTO T176-08 (Verified)
DIME Test ID: 2017-04-03-9-4 AASHTO T304-11 (Verified)
DIME Test ID: 2017-04-03-9-5 ASTM D4791-10 (Verified)
DIME Test ID: 2017-04-03-9-6 CTM 204-June 2010 (Verified)
DIME Test ID: 2017-04-03-9-7 AASHTO T85-13 (Verified)
DIME Test ID: 2017-04-03-9-8 AASHTO T84-14 (Verified)