Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2019-01-09-4

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 213062
DEA: 07292304
EFIS: 0712000109
DIST-CO-RTE-PM07-LA-5-25.6/26.0
Award Date04/04/2018
Closeout Date06/08/2020
Work DescriptionWIDEN OFF-RAMP, WIDEN BRIDGE, AND CONSTRUCT CONCRETE BARRIER.
Location DescriptionLOS ANGELES COUNTY IN LOS ANGELES FROM 0.1 MILE SOUTH TO 0.2 MILE NORTH OF ROUTE 5S/5 SEPARATION
QA Service Level1 (Verified on 04/18/2018)

Sample Information

Sample Taken Date01/09/2019 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/08/2019
Sample typeQuality Assurance A brief description of the sampleDouble Barrel Zap Screwlok
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byDavid Last name of sampler or witnessed byBonon
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameBarSplice CMC Transportation Laboratory (TL) NumberC866888
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC
Coupler ManufacturerBarSplice Intermediate Assembler or FabricatorUnknown
Rebar Size5 Coupler ModelDB ZP Screwlok Trans cp
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)8026 Rebar Heat Number(s)4082429 4082469
Rebar Size 2 6 Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2019-01-09-4-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory02/08/2019Brian
Yes
02/15/2019Bar Broke; OK Necking
2019-01-09-4-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory02/08/2019Brian
Yes
02/15/2019Bar Broke; OK Necking
2019-01-09-4-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory02/08/2019Brian
Yes
02/15/2019Bar Broke; OK Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2019-01-09-4-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-01-09-4-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-01-09-4-3 CTM 670-December 2013 (Verified)