Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2018-08-29-12

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 213152
DEA: 032F5904
EFIS: 0300020624
DIST-CO-RTE-PM03-YUB,NEV-20-20.1/21.7, 0.0/0.1
Award Date05/21/2018
Closeout Date12/06/2021
Work DescriptionCURVE REALIGNMENT AND SHOULDER WIDENING
Location DescriptionYUBA AND NEVADA COUNTIES NEAR SMARTSVILLE FROM 0.5 MILE WEST OF MCGANNEY LANE TO MOONEY FLAT ROAD
QA Service Level1 (Verified on 04/24/2018)

Sample Information

Sample Taken Date08/29/2018 Sample Unique Key12
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/07/2018
Sample typeQuality Assurance A brief description of the sampleFlash Welded Rebar Hoops
The quantity of what the sample constitutes4 From where was the sample collectedManufacturer
First name of sampler or witnessed bySteve Last name of sampler or witnessed byMorris
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameCMC Rebar Tracy Transportation Laboratory (TL) NumberC874432
Inspector Lot Number from the Transportation Laboratory (TL) FormS25-131-18 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Rebar Heat Number(s)4073439
Hoop Manufacturer Lot Number(s)1 Material Standard CodeASTM A706
Material Grade60 Rebar Size7
Diameter of Hoop4'-8" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC Rebar
Welding CompanyCMC Rebar (Tracy) Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2018-08-29-12-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory09/10/2018Brian
Yes
09/17/2018Bar Broke; OK Necking
2018-08-29-12-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory09/10/2018Brian
Yes
09/17/2018Bar Broke; OK Necking
2018-08-29-12-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory09/10/2018Brian
Yes
09/17/2018Bar Broke; OK Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2018-08-29-12-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-08-29-12-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-08-29-12-3 CTM 670-December 2013 (Verified)