Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2018-07-30-1

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 212618
DEA: 044G0564
EFIS: 0417000154
DIST-CO-RTE-PM04-ALA-680-M2.4/M12.4
Award Date11/16/2017
Closeout Date12/08/2022
Work DescriptionROADWAY REHAB, BRIDGE REPLACEMENT, RET. WALLS, TOLL SYSTEMS
Location DescriptionFREMONT AND AT SUNOL FROM MISSION BOULEVARD SEPARATION TO KOOPMAN ROAD UNDERCROSSING
QA Service Level1 (Verified on 10/16/2017)

Sample Information

Sample Taken Date07/30/2018 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/31/2018
Sample typeQuality Assurance A brief description of the sampleBar Lock Couplers
The quantity of what the sample constitutes150 From where was the sample collectedFabricator
First name of sampler or witnessed byJames Last name of sampler or witnessed byDoe
Title of samplerQA Inspector Telephone number of sampler510-918-4918
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameHarris Rebar Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormB358-065-18 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerDayton Superior Intermediate Assembler or FabricatorRamon Tapia
Rebar Size5 Coupler ModelBar Lock Standard
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)Lot C01 and C02 Ht number A150815 Rebar Heat Number(s)3500001280
Rebar Size 2 Not set Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2018-07-30-1-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory08/01/2018Fred
Yes
08/09/2018Service Splice
2018-07-30-1-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory08/01/2018Fred
Yes
08/09/2018Service Splice
2018-07-30-1-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory08/01/2018Fred
Yes
08/09/2018Service Splice
2018-07-30-1-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory08/01/2018Fred
Yes
08/09/2018Service Splice
2018-07-30-1-5CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory08/01/2018Fred
Yes
08/09/2018Service Splice
2018-07-30-1-6CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory08/01/2018Fred
Yes
08/09/2018Service Splice

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2018-07-30-1-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-07-30-1-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-07-30-1-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-07-30-1-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-07-30-1-5 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-07-30-1-6 CTM 670-December 2013 (Verified)