Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2018-06-24-1

Project Information

Project IdentifiersProject ID: 212618
DEA: 044G0564
EFIS: 0417000154
DIST-CO-RTE-PM04-ALA-680-M2.4/M12.4
Award Date11/16/2017
Closeout Date12/08/2022
Work DescriptionROADWAY REHAB, BRIDGE REPLACEMENT, RET. WALLS, TOLL SYSTEMS
Location DescriptionFREMONT AND AT SUNOL FROM MISSION BOULEVARD SEPARATION TO KOOPMAN ROAD UNDERCROSSING
QA Service Level1 (Verified on 10/16/2017)

Sample Information

Sample Taken Date06/24/2018 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing06/29/2018
Sample typeQuality Assurance A brief description of the sampleNo. 9 Grade 75 epoxy coated bars, and hex nuts
The quantity of what the sample constitutes100 From where was the sample collectedManufacturer
First name of sampler or witnessed byEd Last name of sampler or witnessed byFleming
Title of samplerTET Telephone number of sampler707-310-2029
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameWilliams Form Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormB10-162-18 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Threaded Bar Production or Authorization TestingProduction Testing
Threaded Bar SpecificationASTM A615 Threaded Bar Grade75
Threaded Bar TypeDeformed Rebar Size9
Nut Specification for Threaded BarASTM A108 System ManufacturerWilliams Form Eng
Epoxy Coating ColorPurple Threaded Bar ApplicationThreaded Bar
Coating StandardsASTM A934 epoxy Bar Heat Number(s)100792512,100792511,100891184,100888818
Nut Heat Number(s)8296508 Bar Lot Number10079251121,10089118420,10088881821,100792512
Nut Lot Number9J1D Coupler Heat Number(s)
Coupler Grade

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2018-06-24-1-11ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory07/10/2018Fred
Yes
07/18/2018A615 Bar
2018-06-24-1-12ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory07/10/2018Fred
Yes
07/18/2018A615 Bar

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2018-06-24-1-1 ASTM A934-13 (Verified)
DIME Test ID: 2018-06-24-1-2 ASTM A934-13 (Verified)
DIME Test ID: 2018-06-24-1-3 ASTM A934-13 (Verified)
DIME Test ID: 2018-06-24-1-4 ASTM A934-13 (Verified)
DIME Test ID: 2018-06-24-1-5 ASTM A934-13 (Verified)
DIME Test ID: 2018-06-24-1-6 ASTM A934-13 (Verified)
DIME Test ID: 2018-06-24-1-7 ASTM A934-13 (Verified)
DIME Test ID: 2018-06-24-1-8 ASTM A934-13 (Verified)
DIME Test ID: 2018-06-24-1-9 ASTM A934-13 (Verified)
DIME Test ID: 2018-06-24-1-10 ASTM A934-13 (Verified)
DIME Test ID: 2018-06-24-1-11 ASTM A615-15 (Verified)
DIME Test ID: 2018-06-24-1-12 ASTM A615-15 (Verified)