Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2018-05-14-2

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 212618
DEA: 044G0564
EFIS: 0417000154
DIST-CO-RTE-PM04-ALA-680-M2.4/M12.4
Award Date11/16/2017
Closeout Date12/08/2022
Work DescriptionROADWAY REHAB, BRIDGE REPLACEMENT, RET. WALLS, TOLL SYSTEMS
Location DescriptionFREMONT AND AT SUNOL FROM MISSION BOULEVARD SEPARATION TO KOOPMAN ROAD UNDERCROSSING
QA Service Level1 (Verified on 10/16/2017)

Sample Information

Sample Taken Date05/14/2018 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/15/2018
Sample typeQuality Assurance A brief description of the samplebutton headed
The quantity of what the sample constitutes128 From where was the sample collectedFabricator
First name of sampler or witnessed byEd Last name of sampler or witnessed byFleming
Title of samplerTET Telephone number of sampler707-310-2029
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameHarris Rebar Transportation Laboratory (TL) NumberC670951
Inspector Lot Number from the Transportation Laboratory (TL) FormB10-139-18 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)1201000454 Head Manufacturer Lot Number(s)3G1 Heat A162317
Rebar Size5 Headed Bar Model NameBarsplice Buttonhead 10AB
Size of HeadFull Size - 9x Head Connection TypeCrimped Head
Head ShapeCircular Rebar ManufacturerNucor
Head ManufacturerBarsplice Head FabricatorHarris Rebar
Material Standard CodeASTM A706 Headed Bar Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2018-05-14-2-1ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory05/16/2018Fred
Yes
05/23/2018Bar Broke; OK Necking
2018-05-14-2-2ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory05/16/2018Fred
Yes
05/23/2018Bar Broke; OK Necking
2018-05-14-2-3ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory05/16/2018Fred
Yes
05/23/2018Bar Broke; OK Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2018-05-14-2-1 ASTM A970-15e1 (Verified)
DIME Test ID: 2018-05-14-2-2 ASTM A970-15e1 (Verified)
DIME Test ID: 2018-05-14-2-3 ASTM A970-15e1 (Verified)