Sample Record
Owner Lab
- CT HQ - QASI Los Angeles Field Office
DIME Sample ID 2018-02-27-1
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 7613 DEA: 071218W4 EFIS: 0700021119 |
---|---|
DIST-CO-RTE-PM | 07-LA-5-29.4/31.6 |
Award Date | 11/29/2012 |
Closeout Date | 07/31/2023 |
Work Description | REALIGN ROUTE 5 AND RAILROAD TRACKS AND RECONFIGURE ON- AND OFF-RAMPS. |
Location Description | LOS ANGELES COUNTY IN BURBANK FROM WEST MAGNOLIA BOULEVARD OVERCROSSING TO 0.3 MILE NORTH OF BUENA VISTA STREET/WINONA AVENUE UNDERCROSSING |
QA Service Level | 1 (Verified on 10/08/2012) |
Sample Information
Sample Taken Date | 02/27/2018 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/01/2018 |
Sample type | Quality Assurance | A brief description of the sample | Flash Welded Rebar Hoops |
The quantity of what the sample constitutes | 540 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Prakash | Last name of sampler or witnessed by | Patel |
Title of sampler | QA | Telephone number of sampler | 5626654686 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | RKR Steel Welding | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L1100418 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Rebar Heat Number(s) | 0 |
Hoop Manufacturer Lot Number(s) | 1 To 4 | Material Standard Code | ASTM A706 |
Material Grade | 75 | Rebar Size | 8 |
Diameter of Hoop | 5'-2" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | RKR |
Welding Company | RKR Steel Welding | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2018-02-27-1-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-02-27-1-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-02-27-1-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-02-27-1-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-02-27-1-5 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-02-27-1-6 CTM 670-December 2013 (Verified)