Sample Record
Owner Lab
- CT HQ - QASI Los Angeles Field Office
DIME Sample ID 2017-11-14-2
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 11/14/2017 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/17/2017 |
Sample type | Quality Assurance | A brief description of the sample | F1554 Anchor Rods Nuts Washers |
The quantity of what the sample constitutes | 124 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Ken | Last name of sampler or witnessed by | Varela |
Title of sampler | Associate Steel Inspector | Telephone number of sampler | (562) 229-9279 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | A and M Nut and Bolt | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L08 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | N/A |
---|---|---|---|
Heat Number(s) | 3059564 | Nut Mfg. Lot Number(s) | 25179-75065075 |
Washer Mfg. Lot Number(s) | 303301 | Bolt Specification | F1554 |
Bolt Length(s) | 18" | Nut Specification | A194 |
Washer Specification | F436 | Finish | Hot-dip galvanized |
Diameter/Size | 5/8" | Bolt Mfg. Lot Number | 40420-PPO |
Rocap Test Requirement(s) | No | Lubricant Requirements(s) | None |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2017-11-14-2-1 ASTM F606-14a (Verified)
DIME Test ID: 2017-11-14-2-2 ASTM F606-14a (Verified)
DIME Test ID: 2017-11-14-2-3 ASTM F606-14 (Verified)
DIME Test ID: 2017-11-14-2-4 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-11-14-2-5 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-11-14-2-6 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-11-14-2-7 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-11-14-2-8 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-11-14-2-9 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-11-14-2-10 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-11-14-2-11 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-11-14-2-12 ASTM B499-14 (Verified)
DIME Test ID: 2017-11-14-2-13 ASTM B499-14 (Verified)
DIME Test ID: 2017-11-14-2-14 ASTM B499-14 (Verified)
DIME Test ID: 2017-11-14-2-15 ASTM B499-14 (Verified)
DIME Test ID: 2017-11-14-2-16 ASTM B499-14 (Verified)
DIME Test ID: 2017-11-14-2-17 ASTM B499-14 (Verified)
DIME Test ID: 2017-11-14-2-18 ASTM B499-14 (Verified)
DIME Test ID: 2017-11-14-2-19 ASTM B499-14 (Verified)
DIME Test ID: 2017-11-14-2-20 ASTM B499-14 (Verified)
DIME Test ID: 2017-11-14-2-21 ASTM B499-14 (Verified)
DIME Test ID: 2017-11-14-2-22 ASTM B499-14 (Verified)
DIME Test ID: 2017-11-14-2-23 ASTM B499-14 (Verified)
DIME Test ID: 2017-11-14-2-24 ASTM B499-14 (Verified)
DIME Test ID: 2017-11-14-2-25 ASTM E18-15 (Verified)
DIME Test ID: 2017-11-14-2-26 ASTM E18-15 (Verified)