Sample Record
Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
DIME Sample ID 2017-11-10-2
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 211513 DEA: 120M4904 EFIS: 1212000090 |
---|---|
DIST-CO-RTE-PM | 12-ORA-5-1.2/2.2 |
Award Date | 09/20/2016 |
Closeout Date | 01/09/2020 |
Work Description | WIDEN FWY AND BRIDGE AND CONSTRUCT RW, SOUND WALL, AND CONC BARRIERS. |
Location Description | ORANGE COUNTY IN SAN CLEMENTE FROM 0.1 MILE NORTH OF AVENIDA MENDOCINO OVERCROSSING TO 0.2 MILE SOUTH OF AVENIDA PRESIDIO UNDERCROSSING |
QA Service Level | 1 (Verified on 11/03/2016) |
Sample Information
Sample Taken Date | 11/10/2017 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/15/2017 |
Sample type | Quality Assurance | A brief description of the sample | 3/4 in A307 Galvanized Anchor Rod |
The quantity of what the sample constitutes | 300 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Russell | Last name of sampler or witnessed by | Lynch |
Title of sampler | QAI | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Ulmer Industries | Transportation Laboratory (TL) Number | C939725 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L96-210-17 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | 278417 | Nut Mfg. Lot Number(s) | |
Washer Mfg. Lot Number(s) | Bolt Specification | F1554 | |
Bolt Length(s) | 3' | Nut Specification | N/A |
Washer Specification | N/A | Finish | HDG |
Diameter/Size | 3/4 | Bolt Mfg. Lot Number | |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Submitted Tests
Go to page:
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2017-11-10-2-1 ASTM F606-14 (Verified)
DIME Test ID: 2017-11-10-2-2 ASTM F606-14 (Verified)
DIME Test ID: 2017-11-10-2-5 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-11-10-2-6 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-11-10-2-7 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-11-10-2-8 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-11-10-2-9 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-11-10-2-10 ASTM B499-14 (Verified)
DIME Test ID: 2017-11-10-2-11 ASTM B499-14 (Verified)
DIME Test ID: 2017-11-10-2-12 ASTM B499-14 (Verified)
DIME Test ID: 2017-11-10-2-13 ASTM B499-14 (Verified)
DIME Test ID: 2017-11-10-2-14 ASTM B499-14 (Verified)