Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2017-11-10-2

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 211513
DEA: 120M4904
EFIS: 1212000090
DIST-CO-RTE-PM12-ORA-5-1.2/2.2
Award Date09/20/2016
Closeout Date01/09/2020
Work DescriptionWIDEN FWY AND BRIDGE AND CONSTRUCT RW, SOUND WALL, AND CONC BARRIERS.
Location DescriptionORANGE COUNTY IN SAN CLEMENTE FROM 0.1 MILE NORTH OF AVENIDA MENDOCINO OVERCROSSING TO 0.2 MILE SOUTH OF AVENIDA PRESIDIO UNDERCROSSING
QA Service Level1 (Verified on 11/03/2016)

Sample Information

Sample Taken Date11/10/2017 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/15/2017
Sample typeQuality Assurance A brief description of the sample3/4 in A307 Galvanized Anchor Rod
The quantity of what the sample constitutes300 From where was the sample collectedFabricator
First name of sampler or witnessed byRussell Last name of sampler or witnessed byLynch
Title of samplerQAI Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameUlmer Industries Transportation Laboratory (TL) NumberC939725
Inspector Lot Number from the Transportation Laboratory (TL) FormL96-210-17 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)278417 Nut Mfg. Lot Number(s)
Washer Mfg. Lot Number(s) Bolt SpecificationF1554
Bolt Length(s)3' Nut SpecificationN/A
Washer SpecificationN/A FinishHDG
Diameter/Size3/4 Bolt Mfg. Lot Number
Rocap Test Requirement(s) Lubricant Requirements(s)

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2017-11-10-2-13ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory11/15/2017Fred Saylor
Yes
11/23/2017
2017-11-10-2-14ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory11/15/2017Fred Saylor
Yes
11/23/2017

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-11-10-2-1 ASTM F606-14 (Verified)
DIME Test ID: 2017-11-10-2-2 ASTM F606-14 (Verified)
DIME Test ID: 2017-11-10-2-5 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-11-10-2-6 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-11-10-2-7 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-11-10-2-8 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-11-10-2-9 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-11-10-2-10 ASTM B499-14 (Verified)
DIME Test ID: 2017-11-10-2-11 ASTM B499-14 (Verified)
DIME Test ID: 2017-11-10-2-12 ASTM B499-14 (Verified)
DIME Test ID: 2017-11-10-2-13 ASTM B499-14 (Verified)
DIME Test ID: 2017-11-10-2-14 ASTM B499-14 (Verified)