Sample Record
Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
DIME Sample ID 2017-10-20-4
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 211931 DEA: 043G6414 EFIS: 0416000348 |
---|---|
DIST-CO-RTE-PM | 04-NAP-29-37.0 |
Award Date | 03/17/2017 |
Closeout Date | 04/22/2020 |
Work Description | SCOUR REPLACE BRIDGE |
Location Description | NAPA COUNTY IN CALISTOGA AT NAPA RIVER BRIDGE |
QA Service Level | 1 (Verified on 02/15/2017) |
Sample Information
Sample Taken Date | 10/20/2017 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/20/2017 |
Sample type | Quality Assurance | A brief description of the sample | A615 Grade 75 Threaded Bar |
The quantity of what the sample constitutes | 2 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Carolina | Last name of sampler or witnessed by | Margarito |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Williams Form Engineering | Transportation Laboratory (TL) Number | C647235 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L73-012-17 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Threaded Bar | Production or Authorization Testing | Production Testing |
---|---|---|---|
Threaded Bar Specification | ASTM A615 | Threaded Bar Grade | 75 |
Threaded Bar Type | Deformed | Rebar Size | 9 |
Nut Specification for Threaded Bar | 8290539 | System Manufacturer | Williams Form Eng |
Epoxy Coating Color | Purple | Threaded Bar Application | |
Coating Standards | ASTM A934 epoxy | Bar Heat Number(s) | 100786966 |
Nut Heat Number(s) | 8290539 | Bar Lot Number | Unknown |
Nut Lot Number | 9H7D | Coupler Heat Number(s) | NF10100614C |
Coupler Grade | Unknown |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2017-10-20-4-2 ASTM A615-15 (Verified)
DIME Test ID: 2017-10-20-4-3 ASTM A615-15 (Verified)
DIME Test ID: 2017-10-20-4-4 ASTM A934-13 (Verified)