Sample Record

Owner Lab

  • CT HQ - Sacramento Concrete Testing Laboratory

DIME Sample ID 2017-09-21-12

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 212756
DEA: 65A0617
DIST-CO-RTE-PM---
Award DateNot set
Closeout DateNot set
Work DescriptionType 15 FBS , ST-75 Bridge Rail, Type 85 Concrete Bridge Rail
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date09/21/2017 Sample Unique Key12
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/22/2017
Sample typePer Request A brief description of the sampleconcrete cylinders
The quantity of what the sample constitutes2 concrete cylinders From where was the sample collectedSource
First name of sampler or witnessed byMike Last name of sampler or witnessed byMullins
Title of samplertet Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameA and A Concrete Supply Transportation Laboratory (TL) Number136351
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierUnknown
Structure nameUnknown

Material Information

Material TypeConcrete The concrete mix design numberZ5724220
The truck number from where the sample was collectedUnknown The batch plant ticket number from where the sample was collected3083309
Concrete batch plantA and A ready mix Berry ave Sacto The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedat A and A concrete supply Where the material sample would have been placed if not sampledUnknown
From Lot No.Unknown Bag Lot No.Unknown

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2017-09-21-12-1ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensMM, CT HQ - Sacramento Concrete Testing Laboratory10/12/2017MM
Yes
10/12/2017

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-09-21-12-1 ASTM C39-17a (Verified)