Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2017-08-08-12

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 211668
DEA: 010B2604
EFIS: 0112000150
DIST-CO-RTE-PM01-DN-199-8.2
Award Date11/07/2016
Closeout Date01/07/2019
Work DescriptionCONSTRUCT BRIDGE AND WIDEN SHOULDERS
Location DescriptionDEL NORTE COUNTY NEAR HIOUCHI AT 1 MILE NORTH OF SOUTH FORK ROAD
QA Service Level1 (Verified on 09/27/2016)

Sample Information

Sample Taken Date08/08/2017 Sample Unique Key12
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/28/2017
Sample typeQuality Assurance A brief description of the sampleDayton Bar lock couplers
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byJ Last name of sampler or witnessed byCERVANTES
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameNucor Dayton Superior Transportation Laboratory (TL) NumberC944554
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerDayton Superior Intermediate Assembler or FabricatorUnknown
Rebar Size#10 Coupler ModelBar-Lock Standard Couplers
Coating StandardsASTM A775 Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)73100821 Rebar Heat Number(s)PL17103716
Rebar Size 2 Not set Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2017-08-08-12-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory08/29/2017Fred
Yes
09/05/2017Service Splice
2017-08-08-12-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory08/29/2017Fred
Yes
09/05/2017Service Splice
2017-08-08-12-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory08/29/2017Fred
Yes
09/05/2017Service Splice

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-08-08-12-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-08-08-12-2 CTM 670-December 2013 (Verified)