Sample Record

Owner Labs

  • CT SC - 3672 - Fairfield
  • CT HQ - Sacramento Concrete Testing Laboratory

DIME Sample ID 2017-08-02-9

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 212008
DEA: 041SS584
EFIS: 0412000635
DIST-CO-RTE-PM04-MRN-1-2.2
Award Date04/18/2017
Closeout Date12/21/2017
Work DescriptionSOLDIER PILE RETAINING WALL
Location DescriptionMARIN COUNTY AT TAMALPAIS-HOMESTEAD VALLEY 0.3 MILE SOUTH OF WEST CALIFORNIA AVENUE
QA Service Level1 (Verified on 02/15/2017)

Sample Information

Sample Taken Date08/02/2017 Sample Unique Key9
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/29/2017
Sample typeQuality Assurance A brief description of the sampleconc cyl
The quantity of what the sample constitutes2 6x12 cylinders From where was the sample collectedJob Site
First name of sampler or witnessed byJeremy Last name of sampler or witnessed byLight
Title of samplerASR Telephone number of sampler510393-9273
Laboratory sample identification1-28-1 of 2, 2 of 2 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameShamrock Materials Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierUnknown
Structure name27E0073

Material Information

Material TypeConcrete The concrete mix design number4700P
The truck number from where the sample was collected1956 The batch plant ticket number from where the sample was collected156796
Concrete batch plantShamrock San Rafael The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedfrom chute Where the material sample would have been placed if not sampledsoldier piles
From Lot No.Unknown Bag Lot No.Unknown

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2017-08-02-9-1ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensBang, CT HQ - Sacramento Concrete Testing Laboratory08/30/2017Bang
Yes
08/30/2017

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-08-02-9-1 ASTM C39-17a (Verified)