Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2017-07-31-9

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 210040
DEA: 04297624
EFIS: 0400020581
COOP: 042558
DIST-CO-RTE-PM04-ALA-84-22.9/25.7
Award Date09/30/2015
Closeout Date03/12/2020
Work DescriptionWIDENING AND EXPRESSWAY UPGRADES
Location DescriptionON ROUTE 84, FROM RUBY HILL DRIVE TO NORTH OF CONCANNON BOULEVARD
QA Service Level1 (Verified on 11/10/2015)

Sample Information

Sample Taken Date07/31/2017 Sample Unique Key9
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/01/2017
Sample typeQuality Assurance A brief description of the sample5 Flash Welded Hoops
The quantity of what the sample constitutes8 From where was the sample collectedFabricator
First name of sampler or witnessed byEd Last name of sampler or witnessed byFleming
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameMission City Rebar Transportation Laboratory (TL) NumberC740710
Inspector Lot Number from the Transportation Laboratory (TL) FormB1024017 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)158717
Hoop Manufacturer Lot Number(s)1 2 Material Standard CodeASTM A706
Material Grade60 Rebar Size5
Diameter of Hoop3'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCascade
Welding CompanyMission City Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2017-07-31-9-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory08/03/2017Fred
Yes
08/10/2017Bar Broke; OK Necking
2017-07-31-9-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory08/03/2017Fred
Yes
08/10/2017Bar Broke; OK Necking
2017-07-31-9-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory08/03/2017Fred
Yes
08/10/2017Bar Broke; OK Necking
2017-07-31-9-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory08/03/2017Fred
Yes
08/10/2017Bar Broke; OK Necking
2017-07-31-9-5CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory08/03/2017Fred
Yes
08/10/2017Bar Broke; OK Necking
2017-07-31-9-6CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory08/03/2017Fred
Yes
08/10/2017Bar Broke; OK Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-07-31-9-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-07-31-9-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-07-31-9-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-07-31-9-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-07-31-9-5 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-07-31-9-6 CTM 670-December 2013 (Verified)