Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2017-07-31-6

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 209146
DEA: 06471504
EFIS: 0600000464
COOP: 061549
DIST-CO-RTE-PM06-TUL-99-39.6/41.3
Award Date02/24/2017
Closeout Date03/03/2020
Work DescriptionRECONSTRUCT INTERCHANGE WITH NEW PUMPING PLANT.
Location DescriptionTULARE COUNTY AT GOSHEN FROM 0.9 MILE NORTH OF ROUTE 99/198 WEST SEPARATION TO 0.2 MILE NORTH OF NORTH GOSHEN OVERHEAD
QA Service Level1 (Verified on 10/08/2013)

Sample Information

Sample Taken Date07/31/2017 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/31/2017
Sample typeQuality Assurance A brief description of the sample5 rebar DBL BRL ZAP Screwlok
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byAustin Last name of sampler or witnessed byQuiroz
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameCMC BarSplice Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC Rebar
Coupler ManufacturerBarSplice Intermediate Assembler or FabricatorUnknown
Rebar Size5 Coupler ModelDouble Barrel Zap Screwlok
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)5027 5119 Rebar Heat Number(s)4067216
Rebar Size 2 Not set Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2017-07-31-6-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory08/01/2017Fred
Yes
08/08/2017Service Splice
2017-07-31-6-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory08/01/2017Fred
Yes
08/08/2017Service Splice
2017-07-31-6-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory08/01/2017Fred
Yes
08/08/2017Service Splice

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-07-31-6-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-07-31-6-2 CTM 670-December 2013 (Verified)