Sample Record
Owner Lab
- CT HQ - QASI Los Angeles Field Office
DIME Sample ID 2017-07-07-4
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 3807 DEA: 07121844 EFIS: 0700000117 |
---|---|
DIST-CO-RTE-PM | 07-LA-5-42.8/47.3 |
Award Date | 12/06/2010 |
Closeout Date | 06/30/2021 |
Work Description | CONSTRUCT HOV LANES, RETAINING WALLS AND SOUND WALLS. |
Location Description | LOS ANGELES COUNTY IN LOS ANGELES, GLENDALE, AND BURBANK FROM ROUTE 5/134 SEPARATION TO MAGNOLIA BOULEVARD OVERCROSSING |
QA Service Level | 1 (Verified on 02/23/2012) |
Sample Information
Sample Taken Date | 07/07/2017 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/13/2017 |
Sample type | Quality Assurance | A brief description of the sample | 7/8 A325 Bolts, nuts and washers |
The quantity of what the sample constitutes | 402 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Russell | Last name of sampler or witnessed by | Lynch |
Title of sampler | QAI | Telephone number of sampler | (213) 538-8219 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Stinger Bridge Iron | Transportation Laboratory (TL) Number | C970157 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L96-110-17 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | TT0087693 |
---|---|---|---|
Heat Number(s) | 10460750 Bolt 75065073 Nut B40551 Washer | Nut Mfg. Lot Number(s) | 24877-75065073 |
Washer Mfg. Lot Number(s) | 1116-401 | Bolt Specification | A325 |
Bolt Length(s) | 2-1/4" | Nut Specification | A563 |
Washer Specification | F436 | Finish | Mechanically Galvanized |
Diameter/Size | 7/8" | Bolt Mfg. Lot Number | BM0500 |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2017-07-07-4-1 ASTM F606-14a (Verified)
DIME Test ID: 2017-07-07-4-2 ASTM F606-14a (Verified)
DIME Test ID: 2017-07-07-4-3 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-07-07-4-4 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-07-07-4-5 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-07-07-4-6 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-07-07-4-7 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-07-07-4-8 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-07-07-4-9 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-07-07-4-10 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-07-07-4-11 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-07-07-4-12 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-07-07-4-13 ASTM B499-14 (Verified)
DIME Test ID: 2017-07-07-4-14 ASTM B499-14 (Verified)
DIME Test ID: 2017-07-07-4-15 ASTM B499-14 (Verified)
DIME Test ID: 2017-07-07-4-16 ASTM B499-14 (Verified)
DIME Test ID: 2017-07-07-4-17 ASTM B499-14 (Verified)
DIME Test ID: 2017-07-07-4-18 ASTM B499-14 (Verified)
DIME Test ID: 2017-07-07-4-19 ASTM B499-14 (Verified)
DIME Test ID: 2017-07-07-4-20 ASTM B499-14 (Verified)
DIME Test ID: 2017-07-07-4-21 ASTM B499-14 (Verified)
DIME Test ID: 2017-07-07-4-22 ASTM B499-14 (Verified)
DIME Test ID: 2017-07-07-4-23 ASTM B499-14 (Verified)
DIME Test ID: 2017-07-07-4-24 ASTM B499-14 (Verified)
DIME Test ID: 2017-07-07-4-25 ASTM B499-14 (Verified)
DIME Test ID: 2017-07-07-4-26 ASTM B499-14 (Verified)
DIME Test ID: 2017-07-07-4-27 ASTM B499-14 (Verified)
DIME Test ID: 2017-07-07-4-28 ASTM E18-15 (Verified)
DIME Test ID: 2017-07-07-4-29 ASTM E18-15 (Verified)
DIME Test ID: 2017-07-07-4-30 ASTM E18-15 (Verified)
DIME Test ID: 2017-07-07-4-31 ASTM E18-15 (Verified)
DIME Test ID: 2017-07-07-4-32 ASTM E18-15 (Verified)
DIME Test ID: 2017-07-07-4-33 ASTM E18-15 (Verified)