Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2017-06-23-3

Project Information

Project IdentifiersProject ID: 211777
DEA: 04209504
EFIS: 0412000116
DIST-CO-RTE-PM04-MRN,SON-1-50.2/50.5,0.0/0.2
Award Date01/04/2017
Closeout Date10/21/2019
Work DescriptionREPLACE ESTERO BRIDGE AND REALIGN APPROACHING ROADWAY; Bridge No. 27-0121
Location DescriptionMARIN AND SONOMA COUNTIES NEAR VALLEY FORD FROM 0.4 MILE SOUTH OF ESTERO AMERICANO BRIDGE TO 0.2 MILE NORTH OF ESTERO AMERICANO BRIDGE
QA Service Level1 (Verified on 01/17/2017)

Sample Information

Sample Taken Date06/23/2017 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing06/23/2017
Sample typeQuality Assurance A brief description of the sampleFlash welded Rebar Hoops
The quantity of what the sample constitutes4 From where was the sample collectedSource
First name of sampler or witnessed byStacey Last name of sampler or witnessed byDavis
Title of samplerQAI Telephone number of sampler562 480-6984
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameAlamillo Stockton Transportation Laboratory (TL) NumberNA
Inspector Lot Number from the Transportation Laboratory (TL) FormB362-062-17 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)65026869-02
Hoop Manufacturer Lot Number(s)4 Material Standard CodeASTM A706
Material Grade60 Rebar Size8
Diameter of Hoop3'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerTNT Rebar
Welding CompanyAlamillo Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2017-06-23-3-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory06/26/2017Fred
Yes
07/03/2017Bar Broke; OK Necking
2017-06-23-3-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory06/26/2017Fred
Yes
07/03/2017Bar Broke; OK Necking
2017-06-23-3-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory06/26/2017Fred
Yes
07/03/2017Bar Broke; OK Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-06-23-3-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-06-23-3-2 CTM 670-December 2013 (Verified)