Sample Record

Owner Lab

  • CT HQ - QASI Bay Area Field Office

DIME Sample ID 2017-06-20-1

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 211669
DEA: 022C0904
EFIS: 0200000161
DIST-CO-RTE-PM02-PLU-70-50.6/51.7
Award Date11/16/2016
Closeout Date11/12/2020
Work DescriptionBRIDGE WIDENING AND DECK REPLACEMENT, HMA, MGS AND CULVERT REPLACEMENT
Location DescriptionPLUMAS COUNTY NEAR QUINCY FROM 0.6 MILE WEST TO 0.5 MILE EAST OF SPRING GARDEN BRIDGE OVERHEAD
QA Service Level1 (Verified on 10/25/2016)

Sample Information

Sample Taken Date06/20/2017 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/20/2017
Sample typeVerification A brief description of the sample3/4 x 5 1/2 A325 HDG bolt
The quantity of what the sample constitutes7 From where was the sample collectedFabricator
First name of sampler or witnessed byDavid Last name of sampler or witnessed byFlygare
Title of samplerCA METS QA Inspector Telephone number of sampler(801)669-2984
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameUIS Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormB76-062-17 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)none
Heat Number(s)20334170 Nut Mfg. Lot Number(s)
Washer Mfg. Lot Number(s)n/a Bolt SpecificationA325 HDG
Bolt Length(s)5 1/2" Nut Specificationn/a
Washer Specificationn/a FinishHDG
Diameter/Size3/4" x 5 1/2" Bolt Mfg. Lot NumberG7234
Rocap Test Requirement(s)none Lubricant Requirements(s)

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2017-06-20-1-1ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/27/2017Brian
Yes
07/05/2017A325
2017-06-20-1-2ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory06/28/2017Brian Ewing
Yes
07/05/2017
2017-06-20-1-3ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory06/28/2017Brian Ewing
Yes
07/05/2017
2017-06-20-1-4ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory06/28/2017Brian Ewing
Yes
07/05/2017
2017-06-20-1-5ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory06/28/2017Brian Ewing
Yes
07/05/2017
2017-06-20-1-6ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory06/28/2017Brian Ewing
Yes
07/05/2017
2017-06-20-1-7ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory06/28/2017Brian Ewing
Yes
07/05/2017

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-06-20-1-1 ASTM F606-14a (Verified)
DIME Test ID: 2017-06-20-1-2 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-06-20-1-3 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-06-20-1-4 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-06-20-1-5 ASTM B499-14 (Verified)
DIME Test ID: 2017-06-20-1-6 ASTM B499-14 (Verified)