Sample Record
Owner Lab
- CT D01 - Redwood Valley Field Laboratory
DIME Sample ID 2025-01-20-13
Project Information
Project Identifiers | Project ID: 99999 DEA: 0322222 |
---|---|
DIST-CO-RTE-PM | 03-SAC,OMG-888,99,80-0.6-0.6 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES. |
Location Description | THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES. |
QA Service Level | (Verified on 04/05/2013) |
Sample Information
Sample Taken Date | 01/20/2025 | Sample Unique Key | 13 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/28/2025 |
Sample type | Acceptance | A brief description of the sample | Class 2 Agg Base |
The quantity of what the sample constitutes | Per 1000 CY | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Alexis | Last name of sampler or witnessed by | England |
Title of sampler | nerd | Telephone number of sampler | 707 496 8712 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Northern Agg | Transportation Laboratory (TL) Number | 1234A |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Jobsite |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | windrow section 101+40 | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number |
Submitted Tests
DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Submitted By | Verified? | Release Date | Test Comments | Actions |
---|---|---|---|---|---|---|---|---|
2025-01-20-13-1 | CTM 227-December 2014: Method of Test for Evaluating Cleanness of Coarse Aggregate (Cleanness) | Alexis England, CT D01 - Redwood Valley Field Laboratory | 01/28/2025 | Alexis England | No | spec is 60 | Info | |
2025-01-20-13-3 | CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages | Alexis England, CT D01 - Redwood Valley Field Laboratory | 01/28/2025 | Alexis England | No | spec of 95 | Info | |
2025-01-20-13-5 | CTM 212-May 2010: Method of Test for Unit Weight of Aggregate | Alexis England, CT D01 - Redwood Valley Field Laboratory | 02/04/2025 | Alexis England | No | Info | ||
2025-01-20-13-7 | CTM 212-May 2010: Method of Test for Unit Weight of Aggregate | Alexis England, CT D01 - Redwood Valley Field Laboratory | 02/04/2025 | Alexis England | No | Info | ||
2025-01-20-13-8 | CTM 229-June 2011: Method of Test for Durability Index | Alexis England, CT D01 - Redwood Valley Field Laboratory | 02/04/2025 | Alexis England | No | Info |
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2025-01-20-13-1 CTM 227-December 2014
DIME Test ID: 2025-01-20-13-3 CTM 231-March 2013
DIME Test ID: 2025-01-20-13-5 CTM 212-May 2010
DIME Test ID: 2025-01-20-13-7 CTM 212-May 2010
DIME Test ID: 2025-01-20-13-8 CTM 229-June 2011