Sample Record

Owner Labs

  • CT SC - 3674 - Livermore
  • CT HQ - QASI Bay Area Field Office

DIME Sample ID 2024-12-20-4

Project Information

Project IdentifiersProject ID: 209820
DEA: 04297634
EFIS: 0415000040
COOP: 042548
DIST-CO-RTE-PM04-ALA-84,680-17.9/21
Award Date02/19/2021
Closeout DateNot set
Work DescriptionROUTE 84 WIDENING (4-LANE EXPRESSWAY) FROM I-680 TO PIGEON PASS, INCLUDING INTERSECTION, DRAINAGE IMPROVEMENTS AND UTILITY RELOCATION.
Location DescriptionALAMEDA COUNTY IN AND NEAR SUNOL, PLEASANTON, AND LIVERMORE ON ROUTE 84 FROM 0.1 MILE EAST OF ROUTE 680 TO 0.1 MILE SOUTH OF RUBY HILL DRIVE AND ON ROUTE 680 FROM 1.2 MILES SOUTH TO 1.8 MILES NORTH OF ROUTE 84
QA Service Level1 (Verified on 11/04/2019)

Sample Information

Sample Taken Date12/20/2024 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing12/23/2024
Sample typeQuality Assurance A brief description of the sampleStructural Concrete
The quantity of what the sample constitutes162 CY From where was the sample collectedJob Site
First name of sampler or witnessed byIbrahim Last name of sampler or witnessed byMarji
Title of sampler Telephone number of sampler5105094817
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCentral Concrete Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier01-33-0765G
Structure nameVallecitos Creek (N680-E84), Abutment 1

Material Information

Material TypeConcrete The concrete mix design numberD20115EA
The truck number from where the sample was collected6274 The batch plant ticket number from where the sample was collected743381
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedBack of truck Where the material sample would have been placed if not sampledAbutment 1
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2024-12-20-4-1ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensNikhil Moon, CT HQ - Vallejo Field Laboratory01/17/2025Nikhil Moon
Yes
01/22/2025

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-12-20-4-1 ASTM C39-17a (Verified)