Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2017-04-24-2

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 211223
DEA: 010B27U4
EFIS: 0115000111
DIST-CO-RTE-PM01-DN-101-14.9/15.3
Award Date05/11/2016
Closeout Date11/27/2018
Work DescriptionCONSTRUCT RETAINING WALLS AND RECONSTRUCT ROADWAY
Location DescriptionDEL NORTE COUNTY ABOUT 10 MILES NORTH OF KLAMATH FROM 2.2 MILES TO 2.6 MILES NORTH OF WILSON CREEK BRIDGE
QA Service Level1 (Verified on 06/23/2016)

Sample Information

Sample Taken Date04/24/2017 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/11/2017
Sample typeQuality Assurance A brief description of the sampleF1554 Grade 105 HDG Anchor Bolts
The quantity of what the sample constitutes12 From where was the sample collectedJob Site
First name of sampler or witnessed byC Last name of sampler or witnessed byBapat
Title of samplerStructure Representative Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameGaffney Bolt Compant Transportation Laboratory (TL) NumberC944451
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)62140458-03 Nut Mfg. Lot Number(s)308034A
Washer Mfg. Lot Number(s)0812-881 Bolt SpecificationF1554-105 HDG
Bolt Length(s)24" Nut SpecificationA563
Washer SpecificationF436 FinishHDG
Diameter/Size0.875 Bolt Mfg. Lot Number
Rocap Test Requirement(s) Lubricant Requirements(s)

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2017-04-24-2-1ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)Arnold, CT HQ - Sacramento Structural Materials Testing Laboratory05/01/2017Arnold
Yes
05/22/2017F1554 G105
2017-04-24-2-2ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)Arnold Viken, CT HQ - Sacramento Structural Materials Testing Laboratory05/02/2017Arnold Viken
Yes
05/22/2017
2017-04-24-2-3ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)Arnold Viken, CT HQ - Sacramento Structural Materials Testing Laboratory05/02/2017Arnold Viken
Yes
05/22/2017
2017-04-24-2-4ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)Arnold Viken, CT HQ - Sacramento Structural Materials Testing Laboratory05/02/2017Arnold Viken
Yes
05/22/2017
2017-04-24-2-5ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)Arnold Viken, CT HQ - Sacramento Structural Materials Testing Laboratory05/02/2017Arnold Viken
Yes
05/22/2017
2017-04-24-2-6ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)Arnold Viken, CT HQ - Sacramento Structural Materials Testing Laboratory05/02/2017Arnold Viken
Yes
05/22/2017
2017-04-24-2-7ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)Arnold Viken, CT HQ - Sacramento Structural Materials Testing Laboratory05/02/2017Arnold Viken
Yes
05/22/2017
2017-04-24-2-8ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)Arnold, CT HQ - Sacramento Structural Materials Testing Laboratory05/15/2017Arnold
Yes
05/22/2017Nut Proof Load
2017-04-24-2-9ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)Arnold Viken, CT HQ - Sacramento Structural Materials Testing Laboratory05/15/2017Arnold Viken
Yes
05/22/2017
2017-04-24-2-10ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)Arnold Viken, CT HQ - Sacramento Structural Materials Testing Laboratory05/15/2017Arnold Viken
Yes
05/22/2017

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-04-24-2-1 ASTM F606-14 (Verified)
DIME Test ID: 2017-04-24-2-2 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-04-24-2-3 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-04-24-2-4 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-04-24-2-5 ASTM B499-14 (Verified)
DIME Test ID: 2017-04-24-2-6 ASTM B499-14 (Verified)
DIME Test ID: 2017-04-24-2-7 ASTM B499-14 (Verified)
DIME Test ID: 2017-04-24-2-8 ASTM F606-14a (Verified)
DIME Test ID: 2017-04-24-2-9 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-04-24-2-10 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-04-24-2-11 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-04-24-2-12 ASTM B499-14 (Verified)
DIME Test ID: 2017-04-24-2-13 ASTM B499-14 (Verified)
DIME Test ID: 2017-04-24-2-14 ASTM B499-14 (Verified)
DIME Test ID: 2017-04-24-2-15 ASTM B499-14 (Verified)
DIME Test ID: 2017-04-24-2-16 ASTM B499-14 (Verified)
DIME Test ID: 2017-04-24-2-17 ASTM B499-14 (Verified)
DIME Test ID: 2017-04-24-2-18 ASTM E18-15 (Verified)
DIME Test ID: 2017-04-24-2-19 ASTM E18-15 (Verified)