Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2017-04-26-3

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 209708
DEA: 04235524
EFIS: 0412000496
COOP: 042536,042616
DIST-CO-RTE-PM04-SM-92,82-R11.2/10.5
Award Date01/20/2017
Closeout Date02/14/2018
Work DescriptionIMPROVEMENTS TO THE STATE ROUTE (SR) 92/EL CAMINO REAL (SR82) INTERCHANGE
Location DescriptionIN THE CITY OF SAN MATEO
QA Service Level1 (Verified on 10/24/2016)

Sample Information

Sample Taken Date04/26/2017 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/27/2017
Sample typeQuality Assurance A brief description of the sampleBarsplice Button Head End Anchor
The quantity of what the sample constitutes4 From where was the sample collectedFabricator
First name of sampler or witnessed byED Last name of sampler or witnessed byFleming
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameNucor BarSplice Transportation Laboratory (TL) NumberC739992
Inspector Lot Number from the Transportation Laboratory (TL) FormB1018017 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)SE17101134 Head Manufacturer Lot Number(s)T07
Rebar Size#8 Headed Bar Model NameBarsplice Buttonhead 10A
Size of HeadReduced Size - 4x Head Connection Type
Head ShapeCircular Rebar ManufacturerNucor
Head ManufacturerBarsplice Head FabricatorBarsplice
Material Standard CodeASTM A706 Headed Bar Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2017-04-26-3-1ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory04/27/2017Fred
Yes
05/08/2017Bar Broke; OK Necking
2017-04-26-3-2ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory04/27/2017Fred
Yes
05/08/2017Bar Broke; OK Necking
2017-04-26-3-3ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory04/27/2017Fred
Yes
05/08/2017Bar Broke; OK Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-04-26-3-1 ASTM A970-15e1 (Verified)
DIME Test ID: 2017-04-26-3-2 ASTM A970-15e1 (Verified)
DIME Test ID: 2017-04-26-3-3 ASTM A970-15e1 (Verified)