Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2017-04-17-1

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 212164
DEA: 051J1304
EFIS: 0517000064
DIST-CO-RTE-PM05-MON-1-45.52
Award Date02/16/2017
Closeout Date10/25/2019
Work DescriptionPfeiffer Canyon Emergency Bridge Replacement Project
Location DescriptionHighway 1 at Pfeiffer State Park
QA Service Level1 (Verified on 02/27/2017)

Sample Information

Sample Taken Date04/17/2017 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/18/2017
Sample typeQuality Assurance A brief description of the sampleFlash Welded Rebar Hoops
The quantity of what the sample constitutes8 From where was the sample collectedFabricator
First name of sampler or witnessed byED Last name of sampler or witnessed byFleming
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameHarris Rebar Transportation Laboratory (TL) NumberC739977
Inspector Lot Number from the Transportation Laboratory (TL) FormB1016017 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)580967
Hoop Manufacturer Lot Number(s)H04, H05 Material Standard CodeASTM A706
Material Grade60 Rebar Size6
Diameter of Hoop2'-6" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerHarris Rebar
Welding CompanyHarris Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester NameTesting LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2017-04-17-1-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)FredCT HQ - Sacramento Structural Materials Testing Laboratory04/18/2017Fred
Yes
04/25/2017necking okay
2017-04-17-1-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)FredCT HQ - Sacramento Structural Materials Testing Laboratory04/18/2017Fred
Yes
04/25/2017necking okay
2017-04-17-1-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)FredCT HQ - Sacramento Structural Materials Testing Laboratory04/18/2017Fred
Yes
04/25/2017necking okay
2017-04-17-1-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)FredCT HQ - Sacramento Structural Materials Testing Laboratory04/18/2017Fred
Yes
04/25/2017necking okay
2017-04-17-1-5CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)FredCT HQ - Sacramento Structural Materials Testing Laboratory04/18/2017Fred
Yes
04/25/2017necking okay
2017-04-17-1-6CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)FredCT HQ - Sacramento Structural Materials Testing Laboratory04/18/2017Fred
Yes
04/25/2017necking okay