Sample Record

Owner Labs

  • Kwik Bond Polymers
  • CT HQ - Sacramento Concrete Testing Laboratory

DIME Sample ID 2024-11-12-35

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 1000180
DEA: 081N2604
EFIS: 0822000126
DIST-CO-RTE-PM08-SBD-15-2.2/8.5
Award Date05/23/2024
Closeout DateNot set
Work DescriptionFURNISH POLYESTER CONC OVERLAY, PLACE POLYESTER CONC OVERLAY.
Location DescriptionSAN BERNARDINO COUNTY IN AND NEAR FONTANA AT VARIOUS LOCATIONS FROM ROUTE 10 TO ROUTE 210
QA Service Level1 (Verified on 05/15/2024)

Sample Information

Sample Taken Date11/12/2024 Sample Unique Key35
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/13/2024
Sample typeQuality Control A brief description of the sample1 gallon can / PPC 1121 RESIN
The quantity of what the sample constitutes2 tankers From where was the sample collectedSource
First name of sampler or witnessed byGilberto Last name of sampler or witnessed byGonzalez
Title of samplerQuality Control Manager Telephone number of sampler7076245467
Laboratory sample identification000144KBP Linked DIME Sample ID000144KBP
The fabricator/manufacturer/facility nameKwik Bond Polymers, Benicia Transportation Laboratory (TL) NumberSacramento Caltrans lab
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypePolyester Mfg. Lot Number(s)AZ4K01774
Batch numberAZ4K01774 Mix numberAZ4K01774

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2024-11-12-35-1ASTM D638-Dec14: Standard Test Method for Tensile Properties of PlasticsLinda Bergstrom , CT HQ - Sacramento Concrete Testing Laboratory11/19/2024Ryan Tan
Yes
12/31/2024Accepted Vendor's Results
2024-11-12-35-2CTM 551-August 2012: Method of Test for Determining Suitability of Materials for Overlayment and Repair of Portland Cement Concrete Pavements and StructuresGilberto Gonzalez, CT HQ - Sacramento Concrete Testing Laboratory11/21/2024Ryan Tan
Yes
12/31/2024Accepted Vendor's Results
2024-11-12-35-3SCAQMD 309-91-Feb93: Determination of Static Volatile EmissionsGilberto Gonzalez, CT HQ - Sacramento Concrete Testing Laboratory11/20/2024Ryan Tan
Yes
12/31/2024Accepted Vendor's Results

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-11-12-35-1 ASTM D638-Dec14 (Verified)
DIME Test ID: 2024-11-12-35-2 CTM 551-August 2012 (Verified)
DIME Test ID: 2024-11-12-35-3 SCAQMD 309-91-Feb93 (Verified)