Sample Record

Owner Lab

  • CT D08 - Fontana Southern Regional Laboratory

DIME Sample ID 2017-03-17-7

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 211765
DEA: 081G8504
EFIS: 0816000096
MINOR: 08A2744
DIST-CO-RTE-PM08-SBD-83-R0.2/R1.7
Award DateNot set
Closeout DateNot set
Work DescriptionConstruct two (2) gates for Chino Creek Flood Control
Location DescriptionSan Bernadino Country Emergency Project - Construct two (2) gates for Chino Creek Flood Control
QA Service Level1 (Verified on 09/06/2016)

Sample Information

Sample Taken Date03/17/2017 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/21/2017
Sample typeQuality Assurance A brief description of the sampleConcrete Cylinders
The quantity of what the sample constitutes12 From where was the sample collectedJob Site
First name of sampler or witnessed byarnel Last name of sampler or witnessed byvega
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identification956-21 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility namerobertsons Transportation Laboratory (TL) Number20170321
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierUnknown
Structure nameUnknown

Material Information

Material TypeConcrete The concrete mix design numbersc675b39
The truck number from where the sample was collected1049 The batch plant ticket number from where the sample was collected2557657
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedsite Where the material sample would have been placed if not sampledCIDH 1A 1B 2A 2B 2C 2D
From Lot No.Unknown Bag Lot No.Unknown

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2017-03-17-7-1ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensMatthew Clayton, CT D08 - Fontana Southern Regional Laboratory03/22/2017Matthew Clayton
Yes
03/27/2017
2017-03-17-7-2ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensMatthew Clayton, CT D08 - Fontana Southern Regional Laboratory03/24/2017Matthew Clayton
Yes
03/27/2017
2017-03-17-7-3ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensMatthew Clayton, CT D08 - Fontana Southern Regional Laboratory03/27/2017Matthew Clayton
Yes
03/27/2017
2017-03-17-7-4ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensMatthew Clayton, CT D08 - Fontana Southern Regional Laboratory04/03/2017Matthew Clayton
Yes
04/11/2017
2017-03-17-7-5ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensMatthew Clayton, CT D08 - Fontana Southern Regional Laboratory04/14/2017Matthew Clayton
Yes
04/14/2017
2017-03-17-7-6ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensMatthew Clayton, CT D08 - Fontana Southern Regional Laboratory04/28/2017Matthew Clayton
Yes
04/28/2017

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-03-17-7-1 ASTM C39-17a (Verified)
DIME Test ID: 2017-03-17-7-2 ASTM C39-17a (Verified)
DIME Test ID: 2017-03-17-7-3 ASTM C39-17a (Verified)
DIME Test ID: 2017-03-17-7-4 ASTM C39-10 (Verified)
DIME Test ID: 2017-03-17-7-5 ASTM C39-17a (Verified)
DIME Test ID: 2017-03-17-7-6 ASTM C39-17a (Verified)