Sample Record

Owner Lab

  • CT D08 - Fontana Southern Regional Laboratory

DIME Sample ID 2024-10-09-60

Project Information

Project IdentifiersProject ID: 1000216
DEA: 081G6304
EFIS: 0816000043
DIST-CO-RTE-PM08-RIV-111-47.2/55.3
Award Date09/05/2024
Closeout DateNot set
Work DescriptionRHMA-G, REPLACE AC SURFACING, AND COLD PLANE AC PVMT.
Location DescriptionRIVERSIDE COUNTY IN PALM SPRINGS FROM GOLF CLUB DRIVE TO WEST GATEWAY DRIVE
QA Service Level1 (Verified on 05/15/2024)

Sample Information

Sample Taken Date10/09/2024 Sample Unique Key60
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/17/2024
Sample typeVerification A brief description of the sample3/4" HMA A R25 .50% LAS
The quantity of what the sample constitutes4 bags comb agg(3/4,1/2,3/8, 5 rock,crusher fines) 2 bags rap From where was the sample collectedManufacturer
First name of sampler or witnessed byLuke Last name of sampler or witnessed byHall
Title of sampler Telephone number of sampler
Laboratory sample identification0556A-24 Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite Construction Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0072
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collected4 bags comb agg(3/4,1/2,3/8, 5 rock,crusher fines) 2 bags rap
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number1466 Lot number
Sublot number Aggregate Mix Number

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2024-10-09-60-1AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)M.Campos/David Padilla, CT D08 - Fontana Southern Regional Laboratory10/26/2024Satish Jain
No
Combined Virgin Aggregate Gradation Info
2024-10-09-60-2AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)Friday Ofoegbu, CT D08 - Fontana Southern Regional Laboratory10/24/2024Satish Jain
No
Info
2024-10-09-60-3AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)David Padilla, CT D08 - Fontana Southern Regional Laboratory10/23/2024Satish Jain
No
Info
2024-10-09-60-4AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)Seige M, CT D08 - Fontana Southern Regional Laboratory10/28/2024Satish Jain
No
Info
2024-10-09-60-5AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)Ronica B, CT D08 - Fontana Southern Regional Laboratory10/24/2024Satish Jain
No
Info
2024-10-09-60-6AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)Satish Jain, CT D08 - Fontana Southern Regional Laboratory10/26/2024Satish Jain
No
Info
2024-10-09-60-7AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)Satish Jain, CT D08 - Fontana Southern Regional Laboratory10/26/2024Satish Jain
No
Info
2024-10-09-60-8ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)Satish Jain, CT D08 - Fontana Southern Regional Laboratory10/26/2024Satish Jain
No
Info
2024-10-09-60-9CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse AggregatesSeige M, CT D08 - Fontana Southern Regional Laboratory10/30/2024Satish Jain
No
Rap Gradation After Ignition Info
2024-10-09-60-10CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse AggregatesM.Campos/David Padilla/S.M., CT D08 - Fontana Southern Regional Laboratory11/01/2024Satish Jain
No
Comb. Virgin Aggregate Gradation W/Rap Gradation Correlation Factors Info

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-10-09-60-1 AASHTO T27-14
DIME Test ID: 2024-10-09-60-2 AASHTO T84-14
DIME Test ID: 2024-10-09-60-3 AASHTO T85-13
DIME Test ID: 2024-10-09-60-4 AASHTO T96-02r10
DIME Test ID: 2024-10-09-60-5 AASHTO T176-08
DIME Test ID: 2024-10-09-60-6 AASHTO T304-11
DIME Test ID: 2024-10-09-60-7 AASHTO T335-09r13
DIME Test ID: 2024-10-09-60-8 ASTM D4791-10
DIME Test ID: 2024-10-09-60-9 CTM 202-November 2011